2016
DOI: 10.1371/journal.pntd.0004351
|View full text |Cite
|
Sign up to set email alerts
|

Identification of Algerian Field-Caught Phlebotomine Sand Fly Vectors by MALDI-TOF MS

Abstract: BackgroundPhlebotomine sand flies are known to transmit Leishmania parasites, bacteria and viruses that affect humans and animals in many countries worldwide. Precise sand fly identification is essential to prevent phlebotomine-borne diseases. Over the past two decades, progress in matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) has emerged as an accurate tool for arthropod identification. The objective of the present study was to investigate the usefulness of MALDI-… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
71
2
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
8
1

Relationship

4
5

Authors

Journals

citations
Cited by 73 publications
(80 citation statements)
references
References 52 publications
5
71
2
2
Order By: Relevance
“…software (Bruker Daltonics). DB1 included 915 MSPs from eight arthropod families, corresponding to the total MSPs of adult mosquito legs and larvae (Yssouf et al, 2013b(Yssouf et al, ,2014aDieme et al, 2014), tick legs and haemolymph (Yssouf et al, 2013a(Yssouf et al, , 2015a(Yssouf et al, , 2015b as well as sandfly and flea thoraces (Yssouf et al, 2014b;Lafri et al, 2016), which were principally homogenized manually. LSVs reflected MS spectral similarity with reference MS spectra from DB1.…”
Section: Spectra Analysis and Reference Database Upgradingmentioning
confidence: 99%
“…software (Bruker Daltonics). DB1 included 915 MSPs from eight arthropod families, corresponding to the total MSPs of adult mosquito legs and larvae (Yssouf et al, 2013b(Yssouf et al, ,2014aDieme et al, 2014), tick legs and haemolymph (Yssouf et al, 2013a(Yssouf et al, , 2015a(Yssouf et al, , 2015b as well as sandfly and flea thoraces (Yssouf et al, 2014b;Lafri et al, 2016), which were principally homogenized manually. LSVs reflected MS spectral similarity with reference MS spectra from DB1.…”
Section: Spectra Analysis and Reference Database Upgradingmentioning
confidence: 99%
“…Protein mass profiles were obtained using a Microflex LT MALDI-TOF Mass Spectrometer (Bruker Daltonics, Germany), with detection in the linear positive-ion mode at a laser frequency of 50 Hz within a mass range of 2-20 kDa. The setting parameters of the MALDI-TOF MS apparatus were identical to those previously used [44].…”
Section: Methodsmentioning
confidence: 99%
“…The reliability of species identification was estimated using the log score values (LSVs) obtained from the MALDI Biotyper software v.3.0, which ranged from 0 to 3. According to previous studies [26,44], LSVs greater than 1.8 were considered reliable for species identification. Data were analyzed by using GraphPad Prism software version 5.01 (GraphPad, San Diego, CA, USA).…”
Section: Methodsmentioning
confidence: 99%
“…This blind test was performed against our in-lab database, composed of the present CT spectra from P. berghei -infected and non-infected An. stephensi , and also spectra from other arthropod species listed in Table 2 [12, 1518]. The identification level of significance was determined using the log score values (LSVs) given by the MALDI-Biotyper software v.3.3., corresponding to a matched degree of signal intensities of mass spectra of the query and the reference spectra.…”
Section: Methodsmentioning
confidence: 99%