1999
DOI: 10.1016/s0021-9673(99)00256-3
|View full text |Cite
|
Sign up to set email alerts
|

Identification of anthocyanin derivatives in grape skin extracts and red wines by liquid chromatography with diode array and mass spectrometric detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
71
0
5

Year Published

2004
2004
2016
2016

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 158 publications
(79 citation statements)
references
References 11 publications
3
71
0
5
Order By: Relevance
“…The anthocyanin contents of the wines were determined by HPLC-DAD, according to Revilla et al (1999). After filtration through Sartorius filters (Sartorius, USA) (0.45 μm diameter) the samples were injected directly into a a chromatographic system equipped with two pumps Waters 510 and 515, a Rheodyne 7725i injector (20 μm loop) and a photodiode detector Waters 2996 (Waters Corp., USA).…”
Section: Grapesmentioning
confidence: 99%
See 1 more Smart Citation
“…The anthocyanin contents of the wines were determined by HPLC-DAD, according to Revilla et al (1999). After filtration through Sartorius filters (Sartorius, USA) (0.45 μm diameter) the samples were injected directly into a a chromatographic system equipped with two pumps Waters 510 and 515, a Rheodyne 7725i injector (20 μm loop) and a photodiode detector Waters 2996 (Waters Corp., USA).…”
Section: Grapesmentioning
confidence: 99%
“…The solvent A was an aqueous solution (10 %) of formic acid, and solvent B was an aqueous solution of methanol (45 %) and formic acid (10 %). The gradient established was: from 35 to 95 % B for 20 min, from 95 to 100 % B for 5 min, isocratic 100 % B for 5 min (Revilla et al 1999). Two replications of the analyses were performed in all the cases.…”
Section: Grapesmentioning
confidence: 99%
“…Nowadays, the separation technique which is commonly applied is liquid chromatography using mainly C18 reversed-phase columns. This technique combined with UV-Vis (PDA (Photodiode array)) and/or mass spectrometry detectors has been used for the determination of anthocyanin content in various matrices [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27][28].…”
Section: Introductionmentioning
confidence: 99%
“…La composición en pigmentos monoméricos (antocianos y derivados de antocianos) fue analizada por HPLC-DAD, de acuerdo con Revilla et al, 1999 [16]. Se utilizó un sistema cromatográfico compuesto por un inyector Rheodyne 7725i, con un loop de 20 µm, un detector de arreglo de diodos Waters 2296 y dos bombas Waters, 510 y 515 (Waters Corp., USA).…”
Section: Web Of Conferencesunclassified