2006
DOI: 10.1016/j.ijpharm.2006.02.002
|View full text |Cite
|
Sign up to set email alerts
|

Identification of degradation products from aqueous carboplatin injection samples by electrospray mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2006
2006
2018
2018

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 12 publications
0
11
0
Order By: Relevance
“…Identification and structural elucidation of paclitaxel impurities in API beyond threshold limits (0.1%) is mandatory based on the International Conference on Harmonisation (ICH) guidelines 11. There have been a number of reports on strategies involved in identification and structural elucidation of impurities that appear in API12–15 and quantification of related impurities in finished paclitaxel pharmaceutical formulations 16, 17. Although the discovery of electrospray techniques contributed a great deal to the development of new drug candidates, identification of molecular ions of trace level impurities could not be conclusive, due to alkali metal ion adduct formation.…”
Section: Components Of Taxus Brevifolia Extract10mentioning
confidence: 99%
“…Identification and structural elucidation of paclitaxel impurities in API beyond threshold limits (0.1%) is mandatory based on the International Conference on Harmonisation (ICH) guidelines 11. There have been a number of reports on strategies involved in identification and structural elucidation of impurities that appear in API12–15 and quantification of related impurities in finished paclitaxel pharmaceutical formulations 16, 17. Although the discovery of electrospray techniques contributed a great deal to the development of new drug candidates, identification of molecular ions of trace level impurities could not be conclusive, due to alkali metal ion adduct formation.…”
Section: Components Of Taxus Brevifolia Extract10mentioning
confidence: 99%
“…ESI-MS was employed as detector for carboplatin and IS (carboplatin-d4), which made measurement of intact carboplatin precisely. Unlike the method of AAS or ICP-MS measuring platinum as an element, ESI-MS technique that ionizes F I G U R E 2 Percent intact carboplatin following storage of plasma samples with different anticoagulants at room temperature for 0-4 h chemical species and sorts the ions based on their mass-tocharge ratio can detect intact carboplatin directly [6,24]. As we all know, four major nature isotopes of platinum are 194 Pt,195 Pt,196 Pt and 198 Pt, and their natural abundances of 32.9, 33.9, 25.3 and 7.2% [6,10,15].…”
Section: Esi-ms Methods Developmentmentioning
confidence: 99%
“…In another report, Guo and coworkers studied relatively high concentrations of carboplatin (3 mM) using mass spectrometry and reported the existence of a dimer, trimer, and tetramer of the drug [20]. The dimer of carboplatin was also observed in mass spectroscopic studies by Vivekanandan et al [21] and later by us [18,22]. Although mass spectrometry is an ideal way to detect association complexes, solution samples that are injected into the spectrometer are condensed.…”
Section: Self-association Of Carboplatin In Its Ready-to-use Infusionmentioning
confidence: 96%