2013 Ieee Sensors 2013
DOI: 10.1109/icsens.2013.6688479
|View full text |Cite
|
Sign up to set email alerts
|

Identification of different respiratory rate by a piezo polymer based nasal sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 12 publications
0
7
0
1
Order By: Relevance
“…Then, the feature map extracted from the last convolution layer is connected to the fully-connected layer by randomly selecting only the specified proportion of features through dropout after being serialized. Dropout is a technique to select only a part of the entire feature at random, which improves performance over all features [33,34].…”
Section: Proposed Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Then, the feature map extracted from the last convolution layer is connected to the fully-connected layer by randomly selecting only the specified proportion of features through dropout after being serialized. Dropout is a technique to select only a part of the entire feature at random, which improves performance over all features [33,34].…”
Section: Proposed Methodsmentioning
confidence: 99%
“…The 1D CNN method enables various pattern recognition of heart beat signals of ECG sensor. This 1D CNN method shows much higher recognition rate results than SVM or MLP which are traditional machine learning algorithms [33,34]. The structure of the neural network shown in the existing 1D CNN-based signal pattern recognition research uses two or three convolutional layers and fully-connected layers, and shows the classification results in the output layer.…”
Section: Related Researchmentioning
confidence: 99%
“…At the average breathing rate reported in healthy adults at rest is usually administered as 12 breaths per minute (12⋅60 Hz) but estimates vary between sources for example, 12-20 breaths per minute, 10-14, between 16-18, etc [9]. RR that leads to bradypnea (RR <12) or even apnea (respiratory cessation for an indence period) [10]. There are two kinds of breathing mechanisms, namely chest breathing and abdominal breathing [11].…”
Section: Introductionmentioning
confidence: 99%
“…This sensor has advantages such as a small sensor shape, and easy use. This sensor has also been applied to detect and even monitor respiration values [15] [16]. In 2018 the Measurement of Respiratory Rate Using Piezoelectric Sensor was made, by Shankar N, et al detects breathing placed on the patient's chest.…”
Section: Introductionmentioning
confidence: 99%