2017
DOI: 10.3325/cmj.2017.58.141
|View full text |Cite
|
Sign up to set email alerts
|

Identification of myoelectric signals of pregnant rat uterus: new method to detect myometrial contraction

Abstract: AimTo develop an electromyography method for pregnant rat uterus in vivo and to separate myometrial signals from the gastrointestinal tract signals.MethodsPregnant Sprague-Dawley rats (n = 8) were anaesthetized and their stomach, small intestine, and large intestine were removed from the abdomen. A pair of thread electrodes was inserted into the uterus, while a pair of disk electrodes was placed subcutaneously above the myometrium. Additionally, a strain gauge sensor was fixed on the surface of the myometrium … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(8 citation statements)
references
References 15 publications
0
8
0
Order By: Relevance
“…In each dose, the animals were treated with constant intravenous MgSO 4 (0.3 mg/kg) while increasing doses of terbutaline (from 0.05 to 50 μg/kg every 15 min) were added in a cumulative manner. The myoelectric signals of the pregnant uterus, representing the strength of contractions, 14 were detected by an online computer system (SPEL Advanced ISOSYS Data Acquisition System). Uterine contractility was evaluated by fast Fourier transformation (FFT).…”
Section: Methodsmentioning
confidence: 99%
“…In each dose, the animals were treated with constant intravenous MgSO 4 (0.3 mg/kg) while increasing doses of terbutaline (from 0.05 to 50 μg/kg every 15 min) were added in a cumulative manner. The myoelectric signals of the pregnant uterus, representing the strength of contractions, 14 were detected by an online computer system (SPEL Advanced ISOSYS Data Acquisition System). Uterine contractility was evaluated by fast Fourier transformation (FFT).…”
Section: Methodsmentioning
confidence: 99%
“…All analogue signals were filtered with a first-order bandpass Bessel-type filter with a frequency of 1–3 cycles per minute (cpm) and were digitized at a sample rate of 2 Hz. Uterine contractility was evaluated by fast Fourier transformation (FFT), then the power spectrum density maximum (PsD max , the highest peak of PsD) of the SMEMG activity was determined as previously described [ 17 ] ( Fig. 1 .).…”
Section: Methodsmentioning
confidence: 99%
“…The recorded mechanical and myoelectric signals of the in vivo experiments were analyzed by AUC and fast Fourier transformation, respectively. The AUC and PsD max values were determined and compared statistically (Szucs et al, 2016(Szucs et al, , 2017.…”
Section: Discussionmentioning
confidence: 99%
“…In pregnant rats, the electromyographic responses were evaluated by fast Fourier transformation (FFT) and the maximum of power spectrum density (PsD max ) values were compared in the frequency range of 1-3 cpm, which is characteristic for late pregnant uteri (Fig. 3) (Szucs et al, 2017).…”
Section: In Vivo Studiesmentioning
confidence: 99%