2014
DOI: 10.11138/ads/2014.5.4.115
|View full text |Cite
|
Sign up to set email alerts
|

Identification of possible factors influencing temperatures elevation during implant site preparation with piezoelectric technique

Abstract: SummaryBackground. Overheating during implant site preparation negatively affects the osseointegration process as well the final outcome of implant rehabilitations. Piezoelectric techniques seem to provide to a gentle implant preparation although few scientific reports have investigated the heat generation and its underlying factors. Purpose. To investigate, through a proper methodological approach, the main factors influencing temperature rise during piezoelectric implant site preparation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 21 publications
0
2
0
Order By: Relevance
“…Temperature rise during sustained drilling could be explicated by lack of cooling fluid in the deep part of the osteotomy and the blockage caused by bone residue on the drill's cutting edge. Using slower speeds exaggerates this blockage and reduces the drill's cutting efficiency, resulting in more time required to prepare the bone bed and further heat generation (38), which in turn affects the bone tissue viability as proposed in the current study.…”
Section: Discussionmentioning
confidence: 90%
“…Temperature rise during sustained drilling could be explicated by lack of cooling fluid in the deep part of the osteotomy and the blockage caused by bone residue on the drill's cutting edge. Using slower speeds exaggerates this blockage and reduces the drill's cutting efficiency, resulting in more time required to prepare the bone bed and further heat generation (38), which in turn affects the bone tissue viability as proposed in the current study.…”
Section: Discussionmentioning
confidence: 90%
“…The presence of sufficient primary stability of the implant, along with other factors such as minimally traumatic surgical technique (14)(15)(16)(17) and the macro-and micro-geometry of the fixture (18)(19)(20) , has been considered as critical factor in achieving and maintaining implant osseointegration. However, it is more difficult to define and control the various variables that influence the achievement of sufficient primary stability.…”
Section: Discussionmentioning
confidence: 99%