Identity Efficiency for High-Performance Ambient Pressure Ion Mobility Spectrometry

Abstract: A new approach to reduce the false-positive responses commonly encountered in the field when drugs and explosives are detected is reported for an electrospray ionization high-performance ion mobility spectrometry (ESI-HPIMS). In this article, we report on the combination of reduced mobility and the width-at-half-height of a peak to give a new parameter called conditional reduced mobility (CRM). It was found that the CRM was capable of differentiating between real drugs peaks from that of a false-positive peak … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
8
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(9 citation statements)
references
References 44 publications
1
8
0
Order By: Relevance
“…The K0 values of some of these peak signals agreed well with those previously reported in literature, i.e. the protonated monomer of CBD (1.08 ± 0.02 cm 2 V -1 s -1 ) [18] and Δ 9 -THC (1.05 ± 0.0004 and 1.06 cm 2 V -1 s -1 ) [15,18,19]. In these previous studies, only the K0 value of the most intense peak was pointed out in a drift time measurement using TD-IMS [15], while other used electrospray ionization, a soft volatilization/ionization source [18].…”
Section: Optimization Of the Ims Methodologysupporting
confidence: 90%
See 2 more Smart Citations
“…The K0 values of some of these peak signals agreed well with those previously reported in literature, i.e. the protonated monomer of CBD (1.08 ± 0.02 cm 2 V -1 s -1 ) [18] and Δ 9 -THC (1.05 ± 0.0004 and 1.06 cm 2 V -1 s -1 ) [15,18,19]. In these previous studies, only the K0 value of the most intense peak was pointed out in a drift time measurement using TD-IMS [15], while other used electrospray ionization, a soft volatilization/ionization source [18].…”
Section: Optimization Of the Ims Methodologysupporting
confidence: 90%
“…the protonated monomer of CBD (1.08 ± 0.02 cm 2 V -1 s -1 ) [18] and Δ 9 -THC (1.05 ± 0.0004 and 1.06 cm 2 V -1 s -1 ) [15,18,19]. In these previous studies, only the K0 value of the most intense peak was pointed out in a drift time measurement using TD-IMS [15], while other used electrospray ionization, a soft volatilization/ionization source [18]. Moreover, nicotinamide (with a high proton affinity, 918.3 kJ/mol) was employed as an internal calibrant using TD-IMS in the positive ionization mode [15,19].…”
Section: Optimization Of the Ims Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…Some publications are concerned with the reduction of false positive responses commonly encountered in the field when drugs and explosives are detected. 113,114 The topic of this article is the fast and effective detection of syn-…”
Section: Currently Mobile Spectroscopic Techniques Like Infrared (Irmentioning
confidence: 99%
“…With the high sensitivity of IMS, it is possible that disturbing matrix components are detected and generate an alarm due to a false positive result. Some publications are concerned with the reduction of false positive responses commonly encountered in the field when drugs and explosives are detected …”
Section: Introductionmentioning
confidence: 99%