2015 IEEE 13th International Conference on Industrial Informatics (INDIN) 2015
DOI: 10.1109/indin.2015.7281859
|View full text |Cite
|
Sign up to set email alerts
|

IEC 61850 for micro grid automation over heterogeneous network: Requirements and real case deployment

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(3 citation statements)
references
References 19 publications
0
2
0
Order By: Relevance
“…The messages parameters are taken from the automation and automotive application domains, respectively, and the total bandwidth is set to 100 Mbps. The industrial scenario is setup with flow periods in the order of few milliseconds that are typical of the microgrid automation applications (Rinaldi et al 2015), while the topology is chosen to consider the maximum hops that the standard guarantees (i.e., 7 hops). Moreover, the traffic parameters in the automotive case study are inspired from the architecture designed by BMW group .…”
Section: Methodsmentioning
confidence: 99%
“…The messages parameters are taken from the automation and automotive application domains, respectively, and the total bandwidth is set to 100 Mbps. The industrial scenario is setup with flow periods in the order of few milliseconds that are typical of the microgrid automation applications (Rinaldi et al 2015), while the topology is chosen to consider the maximum hops that the standard guarantees (i.e., 7 hops). Moreover, the traffic parameters in the automotive case study are inspired from the architecture designed by BMW group .…”
Section: Methodsmentioning
confidence: 99%
“…Digital substations that rely on fully IP-based communication offer advantages in terms of system integration, system operation, and IT security [4]. In addition to the process-related advantages, digitalized processes enable investigations and analyses that generate additional values in operation that go beyond classic monitoring [5]. Furthermore, transformer stations in low voltage grids are increasingly equipped with integrated measurement devices and provide data for local grid management and for the overlaying control and monitoring processes.…”
Section: Introduction 1motivationmentioning
confidence: 99%
“…There is a growing trend in industrial automation to deploy wireless communication in a hybrid network as an enabler for certain control applications [52][53][54][55][56]. To realize these applications, Ethernet-based wired sub-network has to be interconnected with a wireless segment at the data-link or the application layer [57][58][59].…”
Section: Wireless Extension Of Real-time Ethernetmentioning
confidence: 99%