2018 IEEE Energy Conversion Congress and Exposition (ECCE) 2018
DOI: 10.1109/ecce.2018.8557594
|View full text |Cite
|
Sign up to set email alerts
|

IGCT-Based Direct AC/AC Modular Multilevel Converters for Pumped Hydro Storage Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
25
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 21 publications
(31 citation statements)
references
References 10 publications
0
25
0
Order By: Relevance
“…However, in reality this is unfeasible as the 3x3-MMSC is not capable of operating in the boost mode. So, the theoretical limit for designing the 3x3-MMSC is the one described in equation (5).…”
Section: Improved Converter Topologymentioning
confidence: 99%
See 1 more Smart Citation
“…However, in reality this is unfeasible as the 3x3-MMSC is not capable of operating in the boost mode. So, the theoretical limit for designing the 3x3-MMSC is the one described in equation (5).…”
Section: Improved Converter Topologymentioning
confidence: 99%
“…The amplitude of the grid voltage, connected to the input terminals of the 3x3-MMSC, should be designed according to equation (5), which means that, ideally, V g = V o . However, similarly to the other topologies, a voltage margin is considered and, thus, V g = 1.25(V o ) is adopted for the 3x3-MMSC design.…”
Section: X3-mmsc 1) Number Of Componentsmentioning
confidence: 99%
“…MMC was first developed for and deployed in highvoltage DC inter-ties, where typically low-loss Half-Bridge (HB) Submodules (SMs) are utilized as converter building blocks [12], [13]. In PHSP AC-AC application of interest, either a matrix-like Direct-MMC [14], or a back-to-back (Indirect-)MMC can be considered [10]. While Direct-MMC is superior for new installations with differing machineand grid-side frequencies, Indirect-MMC is more suitable for similar frequency values [15], [14].…”
Section: Introductionmentioning
confidence: 99%
“…In PHSP AC-AC application of interest, either a matrix-like Direct-MMC [14], or a back-to-back (Indirect-)MMC can be considered [10]. While Direct-MMC is superior for new installations with differing machineand grid-side frequencies, Indirect-MMC is more suitable for similar frequency values [15], [14]. As retrofit ideally presumes keeping the original machine, Indirect-MMC is the preferred topology (Fig.…”
Section: Introductionmentioning
confidence: 99%
“…In AC-AC applications, such is a gridconnected drive of the PHSP, either a matrix-like Direct MMC (D-MMC), or a back-to-back Indirect MMC (I-MMC) can be considered. D-MMC is an efficient solution if machine-and grid-frequency differ, making it suitable for new installations, with unrestricted choice of machine parameters [8].…”
Section: Introductionmentioning
confidence: 99%