Ignitability of Unprotected and Retardant Protected Samples of Spruce Wood

Abstract: The paper deals with the protection of the wood and its evaluation in terms of fire. It aims in comparison of ignitability of the unprotected and retardant protected samples of spruce wood, using the testing method defined in the STN EN 11925-2: 2011 (test with single-flame source), where the main evaluation criterion is the ignition and flame spread over the surface of the test samples.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
2
2

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…They are often caused by human negligence, failure to observe fire protection measures-no fire, no smoking, no grass burning, no brushwood burning, playing with matches, etc. In addition, these fires are more dangerous since they occur in the areas which are hard to access for fire brigade and their equipment, with insufficient or unfit resources of water for fire fighting purpose, and require enormous deployment of people, special fire, or aviation technology [15].…”
Section: Coniferous Wood In Forest Firesmentioning
confidence: 99%
“…They are often caused by human negligence, failure to observe fire protection measures-no fire, no smoking, no grass burning, no brushwood burning, playing with matches, etc. In addition, these fires are more dangerous since they occur in the areas which are hard to access for fire brigade and their equipment, with insufficient or unfit resources of water for fire fighting purpose, and require enormous deployment of people, special fire, or aviation technology [15].…”
Section: Coniferous Wood In Forest Firesmentioning
confidence: 99%
“…The reaction to fire of other construction products and building elements (other than electrical cables) is in more detail described in the paper by Mitterova et al (2004).…”
Section: Introductionmentioning
confidence: 99%
“…In our paper we deal with an experimental assessment of selected retarding substances affect (HR-Prof, PLAMOSTOP D and D PLAMOSTOPtransparent), which were applied to the surface of solid spruce wood, and further thermally loaded with a radiant heat source. The evaluation criteria used in the modified test method [3,4], are the relative weight loss of test specimens, the relative rate of burning and the time of ignition.…”
Section: Introductionmentioning
confidence: 99%