Image restoration of motion artifacts in cardiac arteries and vessels based on a generative adversarial network

Abstract: Background: When the heart rate of a patient exceeds the physical limits of a scanning device, even retrospective electrocardiography (ECG) gating technology cannot correct motion artifacts. The purpose of this study was to use deep learning methods to correct motion artifacts in coronary computed tomography angiography (CCTA) images acquired with retrospective ECG gating. Methods: To correct motion artifacts in CCTA images, we used a cycle Wasserstein generative adversarial network with a gradient penalty (WG… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(6 citation statements)
references
References 23 publications
0
6
0
Order By: Relevance
“…(2) the discriminator does not use batch norm, because each sample is independently added with gradient penalty, while batch norm introduces dependency between samples of the same batch. With this enhancement, the WGAN network really improves the problem of pattern collapse in traditional GAN networks [17,18].…”
Section: Wganmentioning
confidence: 99%
“…(2) the discriminator does not use batch norm, because each sample is independently added with gradient penalty, while batch norm introduces dependency between samples of the same batch. With this enhancement, the WGAN network really improves the problem of pattern collapse in traditional GAN networks [17,18].…”
Section: Wganmentioning
confidence: 99%
“…One of the most popular Generative Adversarial Networks is improved Wasserstein generative adversarial network with a gradient penalty (WGAN-GP) 27 , 33 . We used WGAN-GP to synthesize cells images.…”
Section: Methodsmentioning
confidence: 99%
“…[8][9][10] In addition to the hardware, software solutions by means of motion correction in image post processing have also become a common choice, although the principle of various correction algorithms as well as the scanners may both largely differ. [11][12][13] Efforts have also been made in optimizing the vessel enhancement in order to improve the image quality of CCTA. [14][15][16] Mihl et al evaluated a body weight adapted protocol for contrast injection, where a more homogeneous enhancement pattern was achieved between different weight groups while the volume of contrast media could be reduced for the majority of patients.…”
Section: Introductionmentioning
confidence: 99%
“…While applying extra heart rate control via medication and implementing the so‐called retrospective acquisition mode are both efficient measures, the use of a high‐speed wide‐detector CT scanner certainly has its advantage for the ability of acquiring all necessary data within one single heartbeat and less than one rotation 8–10 . In addition to the hardware, software solutions by means of motion correction in image post processing have also become a common choice, although the principle of various correction algorithms as well as the scanners may both largely differ 11–13 …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation