2014
DOI: 10.1107/s160057751400023x
|View full text |Cite
|
Sign up to set email alerts
|

Image stack alignment in full-field X-ray absorption spectroscopy using SIFT_PyOCL

Abstract: Full-field X-ray absorption spectroscopy experiments allow the acquisition of millions of spectra within minutes. However, the construction of the hyperspectral image requires an image alignment procedure with sub-pixel precision. While the image correlation algorithm has originally been used for image re-alignment using translations, the Scale Invariant Feature Transform (SIFT) algorithm (which is by design robust versus rotation, illumination change, translation and scaling) presents an additional advantage:… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
8
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…monochromator with an energy step of 0.3 eV from 3.33 to 3.42 keV for Ag L-edge; and Si(220) with an energy step of 0.3 eV from 4.95 to 4.98 keV and 1 eV from 4.98 to 5.06 keV for Ti K-edge. Data processing was made using the SIFT_PyOCL procedure [27] and TXM-Wizard [28].…”
Section: Synchrotron Based Techniques -Distribution By µXrf and Chemical Speciation By Xanesmentioning
confidence: 99%
“…monochromator with an energy step of 0.3 eV from 3.33 to 3.42 keV for Ag L-edge; and Si(220) with an energy step of 0.3 eV from 4.95 to 4.98 keV and 1 eV from 4.98 to 5.06 keV for Ti K-edge. Data processing was made using the SIFT_PyOCL procedure [27] and TXM-Wizard [28].…”
Section: Synchrotron Based Techniques -Distribution By µXrf and Chemical Speciation By Xanesmentioning
confidence: 99%
“…Full-eld transmission images were compiled and registered to eliminate misalignment and jitter either by Fast Fourier Transform (FFT) or Scale Invariant Feature Transpose (SIFT). 44 Each pixel of the thus registered and compiled image stack contains a full X-ray absorption (XAS) spectrum. The rst 10-20 (pre-edge) points and the last 20-50 (post-edge) points were used to normalize the XAS.…”
Section: Analytical Techniquesmentioning
confidence: 99%
“…This approach is an extension of the one previously described, with extra depth resolved information. In this work the authors combine the advantages of full-field XANES, also exploited elsewhere, 32,33 with confocal micro-Xray fluorescence imaging. This renders elemental distributions, and hence chemical speciation along the cross section on various samples, without any previous preparation.…”
Section: Micro-xas and Multiple Energy Micro-xrf Combined With Micro-xasmentioning
confidence: 99%