2019
DOI: 10.1007/s10278-019-00255-7
|View full text |Cite
|
Sign up to set email alerts
|

Imager-4D: New Software for Viewing Dynamic PET Scans and Extracting Radiomic Parameters from PET Data

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
4
1

Relationship

3
2

Authors

Journals

citations
Cited by 5 publications
(6 citation statements)
references
References 22 publications
0
6
0
Order By: Relevance
“…Compared with other methods where the population‐based input function is used for the entire period of scans, 39 the hybrid approach in this study allows some degree of patient‐specific information in the input function. Based on the patient samples found in this study, the average value of rate constant for the exponential function in the models ( γ ) was found to be −1.38 × 10 −4 (s −1 ) with a standard deviation of 0.34 × 10 −4 (s −1 ).…”
Section: Discussionmentioning
confidence: 99%
“…Compared with other methods where the population‐based input function is used for the entire period of scans, 39 the hybrid approach in this study allows some degree of patient‐specific information in the input function. Based on the patient samples found in this study, the average value of rate constant for the exponential function in the models ( γ ) was found to be −1.38 × 10 −4 (s −1 ) with a standard deviation of 0.34 × 10 −4 (s −1 ).…”
Section: Discussionmentioning
confidence: 99%
“…For patient studies, VOI definition was performed using the Imager-4D software [24]. The IF was determined from a spherical VOI of 15 mm diameter centered in the aorta (Supplementary Fig.…”
Section: Discussionmentioning
confidence: 99%
“…This pilot work has demonstrated the ability of AI-based workflow using DL-CNNs to specifically identify breast cancer tissue as determined by [ 18 F]FDG avidity in a PET/CT study. The high sensitivity and specificity of the network supports the idea that AI can be trained to recognize specific tissue signatures, both normal and disease, in molecular imaging studies using…”
Section: Discussionmentioning
confidence: 99%
“…For this study we used baseline [ 18 F]FDG PET/CT imaging exams acquired as part of two separate multi-institutional clinical trials of patients with breast cancer. The first was TBCRC 008 (NCT00616967) (14), which examined the rate of complete response when using chemotherapy vs chemotherapy + vorinostat in cases of HER2-negative breast cancer.…”
Section: Pet Imaging Studiesmentioning
confidence: 99%
See 1 more Smart Citation