2018
DOI: 10.1093/ehjci/jey136
|View full text |Cite
|
Sign up to set email alerts
|

Imaging-based tricuspid valve anatomy by computed tomography, magnetic resonance imaging, two and three-dimensional echocardiography: correlation with anatomic specimen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
32
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(32 citation statements)
references
References 22 publications
0
32
0
Order By: Relevance
“…Relative to the short mitral hinge line at the septum, the hinge line of the TV at the The septal leaflet warrants a more in-depth description. Characteristically, much of the septal leaflet is indeed septal and shows thin chordae arising from the interventricular septum and attaching on the ventricular surface of the leaflet [29]. However, it has an anterior portion that continues away from the septum to be supported by the medial papillary muscle (of Lancisi) at the antero-septal commissure.…”
Section: How Many Leaflets Has the Valve?mentioning
confidence: 99%
See 2 more Smart Citations
“…Relative to the short mitral hinge line at the septum, the hinge line of the TV at the The septal leaflet warrants a more in-depth description. Characteristically, much of the septal leaflet is indeed septal and shows thin chordae arising from the interventricular septum and attaching on the ventricular surface of the leaflet [29]. However, it has an anterior portion that continues away from the septum to be supported by the medial papillary muscle (of Lancisi) at the antero-septal commissure.…”
Section: How Many Leaflets Has the Valve?mentioning
confidence: 99%
“…However, due to spatial resolution, studying TV leaflets with CMR may be challenging; blurring and ghost artifacts not rarely may deteriorate image quality. Nevertheless, the ability of steady-state free-precession (SSFP) sequences to obtain strong signal from fat and blood and weak signal from myocardium enables clarification of specific anatomic details of the tricuspid annulus and the pyramidal space [ 29 ]. Needless to say, CMR is the gold standard for evaluating right ventricular size and function and may be useful in grading TR in challenging cases.…”
Section: Which Is the Best Noninvasive Imaging Technique To Visualize Tv?mentioning
confidence: 99%
See 1 more Smart Citation
“…With the exclusion of the small septal area, the EAT covers the entire C-shaped AV groove around the tricuspid valve orifice. [17] As for the left AV groove, this anatomical arrangement assures an excellent electrical insulation between the atrial and the ventricular myocardium [Figure 7].…”
Section: The Right Atrioventricular Groove and The Tricuspid Annulusmentioning
confidence: 99%
“…For example, Praz et al. ( 8 ) outlined an algorithm for successful pre-procedural planning for valve selection based on simulation by CT scanning of 21 patients with severe MAC who underwent hybrid transatrial TMVR ( 11 ).…”
mentioning
confidence: 99%