CT of the Heart 2005
DOI: 10.1385/1-59259-818-8:195
|View full text |Cite
|
Sign up to set email alerts
|

Imaging Intramyocardial Microcirculatory Function Using Fast Computed Tomography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

2
0
0

Year Published

2015
2015
2016
2016

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 104 publications
2
0
0
Order By: Relevance
“…In the dog study, all PVC methods led to reduced IMBV for this high count data, indicating the effectiveness of PVC to correct for the overestimation effect. Although no gold standard approach was applied to determine IMBV in the current study, previous studies (Möhlenkamp et al 2005, Vogel et al 2005 suggested that the typical IMBV for normal dogs was in the range between 10%-20%, which was consistent with our results after PVC. In future studies, we will validate in vivo IMBV quantified by the SPECT/CT approach against ex vivo myocardium specimens imaging using ultra-high resolution microCT as the gold standard of IMBV (Malyar et al 2004).…”
Section: Discussionsupporting
confidence: 91%
“…In the dog study, all PVC methods led to reduced IMBV for this high count data, indicating the effectiveness of PVC to correct for the overestimation effect. Although no gold standard approach was applied to determine IMBV in the current study, previous studies (Möhlenkamp et al 2005, Vogel et al 2005 suggested that the typical IMBV for normal dogs was in the range between 10%-20%, which was consistent with our results after PVC. In future studies, we will validate in vivo IMBV quantified by the SPECT/CT approach against ex vivo myocardium specimens imaging using ultra-high resolution microCT as the gold standard of IMBV (Malyar et al 2004).…”
Section: Discussionsupporting
confidence: 91%
“…For the IMBV measurement, all the PVC methods yielded a reasonable estimation of IMBV except for the MTC approach with low count data. Although no gold standard approach was applied to determine IMBV in the current study, previous studies 44,45 suggest that the typical IMBV for normal dogs is in the range between 15% and 20%, which is consistent with our results after PVC. We will validate the IMBV measurement against the analysis of ex vivo myocardium specimens imaging using ultrahigh resolution microCT as the gold standard of IMBV in the future study.…”
Section: B Animal Studysupporting
confidence: 91%