2017
DOI: 10.1088/1612-202x/aa58b7
|View full text |Cite
|
Sign up to set email alerts
|

Imaging of trabecular meshwork using Bessel–Gauss light sheet with fluorescence

Abstract: Ocular imaging technology that holds promise for both fundamental investigation and clinical detection of glaucoma is still a challenging research area. A direct view of the trabecular meshwork (TM) with high resolution is not generally possible because the iridocorneal angle region is obstructed by the sclera overlap. The best approach to observe the aqueous outflow system (AOS) is therefore to view from the opposite angle. In this research work, we developed two imaging systems for the high resolution ex viv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
13
0

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
2

Relationship

5
1

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 30 publications
1
13
0
Order By: Relevance
“…The invariant intensity over a large focal region and the self‐reconstructive property of the Bessel beam makes it an ideal source for illuminating structures within scattering media. Additionally, the scanned light sheet illuminates the sample with identical intensity at each scanned line, and enables quantitative analysis of large samples in their natural state . The adopted method of generating the Bessel beam using an axicon lens can be easily implemented and is more efficient than traditional methods such as the illumination of an annular mask .…”
Section: Resultssupporting
confidence: 83%
See 2 more Smart Citations
“…The invariant intensity over a large focal region and the self‐reconstructive property of the Bessel beam makes it an ideal source for illuminating structures within scattering media. Additionally, the scanned light sheet illuminates the sample with identical intensity at each scanned line, and enables quantitative analysis of large samples in their natural state . The adopted method of generating the Bessel beam using an axicon lens can be easily implemented and is more efficient than traditional methods such as the illumination of an annular mask .…”
Section: Resultssupporting
confidence: 83%
“…This technique can generate high resolution two‐dimensional optical sections of the samples under investigation . With this perspective we consider Bessel beam‐based scanned light sheet fluorescence microscopy (LSFM), as a potential imaging modality that can produce high resolution optical sections with minimal phototoxicity and photobleaching . The high speed data acquisition and low photodamage of this technique make it an ideal candidate for in vivo ocular imaging.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, this positioning improves the image sharpness and reduces background noise. 26 The proposed LSFM scheme has an intrinsic optical sectioning capability, because no fluorescence is generated beyond the illumination plane, minimizing the out-of-focus background.…”
Section: Imaging Methods For Ica Regionmentioning
confidence: 99%
“…With minor modifications, the excitation arm of the proposed ICA imaging system can be adapted for high-resolution corneal imaging. Although we have reported the Bessel beam light sheet fluorescence microscopy (LSFM)based ICA imaging system and Gaussian beam based corneal imaging system in the past, 25,26 a method to integrate these two techniques to a single system that can be used for both corneal imaging and ICA imaging is reported in this work. Further the in vivo and ex vivo imaging capabilities of this system are also demonstrated as proof of concept.…”
Section: Problem Identificationmentioning
confidence: 99%