2023
DOI: 10.3390/jcm12041248
|View full text |Cite
|
Sign up to set email alerts
|

Immediate Effects of Myofascial Release Treatment on Lumbar Microcirculation: A Randomized, Placebo-Controlled Trial

Abstract: (1) Background: Inflammatory processes in the thoracolumbar fascia (TLF) lead to thickening, compaction, and fibrosis and are thought to contribute to the development of nonspecific low back pain (nLBP). The blood flow (BF) of fascial tissue may play a critical role in this process, as it may promote hypoxia-induced inflammation. The primary objective of the study was to examine the immediate effects of a set of myofascial release (MFR) techniques on the BF of lumbar myofascial tissue. The secondary objectives… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 20 publications
(13 citation statements)
references
References 58 publications
0
13
0
Order By: Relevance
“…The PTM proved to be suitable for measurements of compressive stiffness, the latter being characterized by a force acting perpendicularly on the material. However, the design of the model did not allow investigations of shear strains, which would involve a force applied laterally to the medium ( Langevin et al, 2011 ; Krause et al, 2016 ; Brandl et al, 2023a , 2023b ). In both diagnostic measurements and therapeutic applications, shear mobility between tissue layers can play a significant role in determining muscle and fascia health.…”
Section: Discussionmentioning
confidence: 99%
“…The PTM proved to be suitable for measurements of compressive stiffness, the latter being characterized by a force acting perpendicularly on the material. However, the design of the model did not allow investigations of shear strains, which would involve a force applied laterally to the medium ( Langevin et al, 2011 ; Krause et al, 2016 ; Brandl et al, 2023a , 2023b ). In both diagnostic measurements and therapeutic applications, shear mobility between tissue layers can play a significant role in determining muscle and fascia health.…”
Section: Discussionmentioning
confidence: 99%
“…The device determined these parameters at the venous end of the capillary and thus provided information about the local microcirculation. The measurement procedure is described in detail in Brandl et al [ 14 ]. Briefly, the average values over 10 seconds were derived at a sampling rate of 40 Hz for blood flow by laser Doppler spectroscopy and 2 Hz for SO 2 and rHb by white light spectroscopy.…”
Section: Methodsmentioning
confidence: 99%
“…The O2C fiber probe was fixed pressure-free with a transparent double-sided adhesive film (Lea Medizintechnik, Giessen, Germany). The ICC value for the measurement was calculated in a previous study and was reported to be excellent (ICC = 0.99) [ 14 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations