2013
DOI: 10.1016/j.msec.2012.08.003
|View full text |Cite
|
Sign up to set email alerts
|

Immobilization of Acidithiobacillus ferrooxidans on sulfonated microporous poly(styrene–divinylbenzene) copolymer with granulated activated carbon and its use in bio-oxidation of ferrous iron

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 32 publications
1
5
0
Order By: Relevance
“…According to Table 1, the maximum ferrous iron biooxidation rate (R) of 2.46 kg m -3 h -1 was obtained at the highest dilution rate (D) with biological oxidation efficiency of 70.2%. A comparable result was reported by Koseoglu-Imer and Keskinler [11], which have employed sulfonated poly (styrene-divinylbenzene) copolymer with granular activated carbon for Figure 5. Schematic of bioreactor: (1) packed bed column, (2) fresh medium, (3) peristaltic pump, (4) air pump, (5) gas flow meter, (6) filter, (7) humidifier, (8) effluent culture immobilization of A. ferrooxidans.…”
Section: Continuous Bio-oxidationsupporting
confidence: 84%
See 3 more Smart Citations
“…According to Table 1, the maximum ferrous iron biooxidation rate (R) of 2.46 kg m -3 h -1 was obtained at the highest dilution rate (D) with biological oxidation efficiency of 70.2%. A comparable result was reported by Koseoglu-Imer and Keskinler [11], which have employed sulfonated poly (styrene-divinylbenzene) copolymer with granular activated carbon for Figure 5. Schematic of bioreactor: (1) packed bed column, (2) fresh medium, (3) peristaltic pump, (4) air pump, (5) gas flow meter, (6) filter, (7) humidifier, (8) effluent culture immobilization of A. ferrooxidans.…”
Section: Continuous Bio-oxidationsupporting
confidence: 84%
“…The free cell concentration was directly counted using a Neubauer chamber (haemocytometer) of 0.1 mm depth and 1/400 mm 2 area. Ferrous iron concentration was determined by a colorimetric procedure using 1,10-phenanthroline method [11]. Scanning Electron Microscopy (SEM) (model MIRA III, TESCAN, Czech Republic) analysis was carried out for monitoring the surface of the hemp fibres.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Owing to the natural tendency of A. ferrooxidans , the biological oxidation rate can be enhanced by immobilized A. ferrooxidans . Therefore, the immobilization of A. ferrooxidans was widely studied in an attempt to increase ferrous iron oxidation rate .…”
Section: Introductionmentioning
confidence: 99%