Immobilization of rat brain acetylcholinesterase on porous gold-nanoparticle–CaCO3 hybrid material modified Au electrode for detection of organophosphorous insecticides

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
19
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(23 citation statements)
references
References 41 publications
3
19
0
1
Order By: Relevance
“…5d). This phenomenon was also observed by others [29][30][31]. The cathodic peak might be attributed to the reduction of the thiocholine and the mechanism is currently being investigated.…”
Section: Cyclic Voltammetric Behaviors Of the Ache-mwcnt-ca-npg Electsupporting
confidence: 77%
See 1 more Smart Citation
“…5d). This phenomenon was also observed by others [29][30][31]. The cathodic peak might be attributed to the reduction of the thiocholine and the mechanism is currently being investigated.…”
Section: Cyclic Voltammetric Behaviors Of the Ache-mwcnt-ca-npg Electsupporting
confidence: 77%
“…Recently, a number of AChE biosensors have been developed for malathion. However, the detection limits were calculated in different ways [29,36,37]. Our reported value is much lower or comparable to those in the references [30,38].…”
Section: Calibration Curve For Malathion Determinationsupporting
confidence: 70%
“…Nevertheless, they are time consuming and laborious, and require expensive equipments and highly trained technicians. [9] As a good alternative and with the improvement of being quick and consistent, several bioanalytical techniques based on inhibition of acetylcholinesterase (AChE) and coupled with simple detectors have been developed recently. [10,11] Biosensors are considered a viable alternative to the chromatographic methods for pesticide determination for an on-site analysis.…”
Section: Introductionmentioning
confidence: 99%
“…The detection limits and linear ranges obtained in this work were similar to, or better than, many reported in the literature using other sensors. 10,12,[30][31][32][33][34][35][36][37][38][39][40][41][42][43] This can be attributed to the efficiency of electron transfer between the CoTSPc/CNT/OMIM[BF4]/AChE biosensor and TCh, due to the catalytic effect of the CoTSPc/CNT/OMIM[BF4] composite. In addition, the reaction occurring at the CoTSPc/ CNT/OMIM[BF4]/AChE biosensor very quickly reached a dynamic equilibrium after each addition of the analyte, with a response time of less than 1 s for the signal to reach 100%.…”
Section: Study Of the Incubation Time Of The Cotspc/cnt/omim[bf4]/ Acmentioning
confidence: 99%