2020
DOI: 10.1016/j.jtice.2020.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Immuno-probed graphene nanoplatelets on electrolyte-gated field-effect transistor for stable cortisol quantification in serum

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 20 publications
(20 citation statements)
references
References 36 publications
2
16
0
Order By: Relevance
“…Further, when albumin and globulin were dropped on aptamer‐modified surfaces instead of LH, there was no current response recorded (Figure 5B). Globulin (2.6–3.5 g/dl) and albumin (3.5–5.0 g/dl) are the major and predominant proteins in the blood serum with the molecular sizes of ∼150 and 66.5 kDa, respectively 38 . Present study is embarked to demonstrate the genuine interaction between aptamer and LH in the presence of these proteins, which supports the condition with the real sample analysis.…”
Section: Resultssupporting
confidence: 79%
See 1 more Smart Citation
“…Further, when albumin and globulin were dropped on aptamer‐modified surfaces instead of LH, there was no current response recorded (Figure 5B). Globulin (2.6–3.5 g/dl) and albumin (3.5–5.0 g/dl) are the major and predominant proteins in the blood serum with the molecular sizes of ∼150 and 66.5 kDa, respectively 38 . Present study is embarked to demonstrate the genuine interaction between aptamer and LH in the presence of these proteins, which supports the condition with the real sample analysis.…”
Section: Resultssupporting
confidence: 79%
“…Globulin (2.6-3.5 g/dl) and albumin (3.5-5.0 g/dl) are the major and predominant proteins in blood serum with the molecular sizes of ∼150 and 66.5 kDa, respectively. 38 Present study is embarked to demonstrate the genuine interaction between aptamer and LH in the presence of these proteins, which supports the condition with the real sample analysis. These overall results confirm that our aptamer-modified sensing electrode surface did not show any biofouling effect and it only allows the specific interaction of LH with aptamer.…”
Section: Biofouling Of Control Molecules On Go-aptamer-modified Elect...supporting
confidence: 73%
“…The sensor is limited by the adsorption kinetics of MIP as evident by logarithmic sensitivity compared to linear sensitivity offered by some sensors reported in Tables S1 and S2. While the prepared sensor exhibits better sensitivity compared to other PPy based MIP, it falls short compared to some reported cortisol immunosensor [72 μA log –1 (g/mL)] . One of the future endeavors is to leverage computational tools which can help in characterization and optimization of materials and methods to enhance sensitivity and performance of the sensor …”
Section: Resultsmentioning
confidence: 97%
“…While the prepared sensor exhibits better sensitivity compared to other PPy based MIP, 17 it falls short compared to some reported cortisol immunosensor [72 μA log −1 (g/mL)]. 27 One of the future endeavors is to leverage computational tools which can help in characterization and optimization of materials and methods to enhance sensitivity and performance of the sensor. 9 The response of the MIP can be fitted to an adsorption isotherm to understand the affinity of MIP toward the target.…”
Section: Analytical Performancementioning
confidence: 94%
See 1 more Smart Citation