2005
DOI: 10.1016/j.bios.2004.09.024
|View full text |Cite
|
Sign up to set email alerts
|

Immunoassay of prostate-specific antigen (PSA) using resonant frequency shift of piezoelectric nanomechanical microcantilever

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
71
0
1

Year Published

2005
2005
2015
2015

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 188 publications
(72 citation statements)
references
References 15 publications
0
71
0
1
Order By: Relevance
“…The reported benefits of using nanocantilever systems in cancer detection include that there are no requirements for fluorescent or radioactive labeling; detection may take place in liquid samples and this technology may be easily translated to lab-on-a-chip techniques, providing point-of-care diagnostics (16). They have also been described as a simple replacement to polymerase chain reaction reactions and detection methods, as they are more cost-effective regarding sample preparation, in terms of time and costly materials.…”
Section: Cantileversmentioning
confidence: 99%
“…The reported benefits of using nanocantilever systems in cancer detection include that there are no requirements for fluorescent or radioactive labeling; detection may take place in liquid samples and this technology may be easily translated to lab-on-a-chip techniques, providing point-of-care diagnostics (16). They have also been described as a simple replacement to polymerase chain reaction reactions and detection methods, as they are more cost-effective regarding sample preparation, in terms of time and costly materials.…”
Section: Cantileversmentioning
confidence: 99%
“…This is by far the most sensitive method, even if significantly more complex than that for deflection-based detection [122]. Using this more sensitive resonancebased measurement strategy, PSA with an LOD of 10 pg mL -1 was detected [128]. The incorporation of piezoelectric materials into microcantilevers can also be used to monitor the presence of biomolecules.…”
Section: Micro-cantilever Immunosensorsmentioning
confidence: 99%
“…Analyte binding to the cantilever surface causes the cantilever to deflect, consequently depolarising the material and generating a current. A piezoelectric nanomechanical cantilever was fabricated by Lee et al for the label free detection of PSA with an LOD of 10 pg mL -1 [130].…”
Section: Micro-cantilever Immunosensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…When a cantilever biosensor operates in static mode, the deflection resulted from the surface stress of the adsorbed biomaterials has been measured by optical measurement system [6,7], which is so bulky and expensive that it is almost impossible to minimize the device size for a Lab-On-a-Chip (LOC) system. There are other detection limitations such as a narrow dynamic range and parasitic deflection in optical measurements [8].…”
Section: Introductionmentioning
confidence: 99%