2020
DOI: 10.3390/su12072950
|View full text |Cite
|
Sign up to set email alerts
|

Impact of Adding Comfort Cooling Systems on the Energy Consumption and EPC Rating of an Existing UK Hotel

Abstract: In light of the recent launch of the Minimum Energy Efficiency Standard and its expected impact on the commercial buildings sector, this study investigated the impact of adding cooling systems on the annual energy consumption, carbon dioxide emissions and energy performance certificate (EPC) rating of an existing UK hotel. Thermal Analysis Software (TAS) was used to conduct the study, and the baseline model was validated against the actual data. As is the current accepted procedure in EPC generating in the UK,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 30 publications
0
2
0
Order By: Relevance
“…Deep changes in consumers' demand and suppliers' offers are required to shape the market of cooling, moving towards considering more variables which directly impact thermal comfort, including temperature, humidity, radiant temperature, air velocity, clothing and metabolic rate (BCA 2015). It is suggested to eliminate the criteria of a fixed AC set-point temperature to fulfil building regulation requirements and calculate EPCs for buildings (Amirkhani et al 2020;CREDS 2018;IDAE 2009; Ministerio de Fomento del Gobierno de España 2020; UK Government 2021). For example, integrating fans to increase airspeed with ACs can also increase the set-point temperature from 25 to 27°C without sacrificing thermal comfort, reducing energy consumption by more than 21% (Hoyt et al 2015;Luo et al 2021;Malik et al 2022;Schiavon & Melikov 2008).…”
Section: Acs To Consider Multiple Thermal Comfort Parametersmentioning
confidence: 99%
See 1 more Smart Citation
“…Deep changes in consumers' demand and suppliers' offers are required to shape the market of cooling, moving towards considering more variables which directly impact thermal comfort, including temperature, humidity, radiant temperature, air velocity, clothing and metabolic rate (BCA 2015). It is suggested to eliminate the criteria of a fixed AC set-point temperature to fulfil building regulation requirements and calculate EPCs for buildings (Amirkhani et al 2020;CREDS 2018;IDAE 2009; Ministerio de Fomento del Gobierno de España 2020; UK Government 2021). For example, integrating fans to increase airspeed with ACs can also increase the set-point temperature from 25 to 27°C without sacrificing thermal comfort, reducing energy consumption by more than 21% (Hoyt et al 2015;Luo et al 2021;Malik et al 2022;Schiavon & Melikov 2008).…”
Section: Acs To Consider Multiple Thermal Comfort Parametersmentioning
confidence: 99%
“…Tools to simulate the energy demand of buildings in order to fulfil building codes, emit EPCs or size AC systems use a fixed set-point temperature to calculate cooling needs. For example, in the case of Spain and the UK for cooling, the set-point temperature for EPCs is defined at 25°C (Amirkhani et al 2020;IDAE 2009; Ministerio de Fomento del Gobierno de España 2020). The steady-state approach (or PMV/PPD method) proposed by Fanger (1970) predicts the mean thermal sensation and percentage of dissatisfaction of a given group of people in the environment considering all comfort parameters.…”
mentioning
confidence: 99%