1996
DOI: 10.1016/s0883-5403(96)80026-x
|View full text |Cite
|
Sign up to set email alerts
|

Impact of gamma sterilization on clinical performance of polyethylene in the knee

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
127
0
3

Year Published

1998
1998
2012
2012

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 257 publications
(134 citation statements)
references
References 12 publications
4
127
0
3
Order By: Relevance
“…On the one hand, the crosslinking imparted by a single sterilization dose (25-40 kGy) of gamma radiation substantially improved its wear resistance [29,55] and contributed to the long-term clinical success of the metal-on-polyethylene wear couple used in hip and knee arthroplasty to this day. Gamma sterilization in the presence of air also had a drawback in that it rendered the polymer vulnerable to oxidation before implantation [81,113] and during in vivo exposure [30,36,78,82,129]. It would take decades, however, for gamma sterilization in air to be challenged as the industry standard for polyethylene, because the deleterious effects of oxidation in polyethylene take many years to manifest [81].…”
Section: History and Development Of Hxlpementioning
confidence: 99%
“…On the one hand, the crosslinking imparted by a single sterilization dose (25-40 kGy) of gamma radiation substantially improved its wear resistance [29,55] and contributed to the long-term clinical success of the metal-on-polyethylene wear couple used in hip and knee arthroplasty to this day. Gamma sterilization in the presence of air also had a drawback in that it rendered the polymer vulnerable to oxidation before implantation [81,113] and during in vivo exposure [30,36,78,82,129]. It would take decades, however, for gamma sterilization in air to be challenged as the industry standard for polyethylene, because the deleterious effects of oxidation in polyethylene take many years to manifest [81].…”
Section: History and Development Of Hxlpementioning
confidence: 99%
“…Shelf storage time before implantation was a concern for gamma-air-sterilized inserts [4,7,9] where shelf oxidation led to early in vivo fatigue damage. Some early barrier packaging did not effectively prevent shelf oxidation [6], but the change from gamma-air to gamma-inert sterilization largely prevented the shelf oxidation that led to fatigue after less than 4 years in vivo [5]. In vivo oxidation was predicted to increase exponentially with time [9,12].…”
Section: Discussionmentioning
confidence: 99%
“…Thin sections were prepared using a technique developed to permit static mechanical testing of the surface, subsurface, and bulk regions of the tibial bearings [5]. Two sagittal cuts, 6 mm apart, were made from the anterior to the posterior surface of the tibial bearings using a band saw.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations