2019
DOI: 10.1111/clr.13490
|View full text |Cite
|
Sign up to set email alerts
|

Impact of number of registration points on the positional accuracy of a prosthetic treatment plan incorporated into a cone beam computed tomography scan by surface scan registration: An in vitro study

Abstract: Objectives:To evaluate the accuracy of a prosthetic treatment plan incorporation into a cone beam computed tomography (CBCT) scan using point-based registration with three registration points selected and to evaluate the impact of number of registration points on prosthetic plan accuracy. Material and Methods:A CBCT scan of a completely dentate master model with removable teeth was exposed after removing the mandibular left first premolar, second premolar, and first molar. A digital scan of the master model wi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2020
2020
2025
2025

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(8 citation statements)
references
References 23 publications
0
8
0
Order By: Relevance
“…Because dentition constitutes an optical and radiographic marker, alignment was conducted based on the natural teeth. 32,33 This method may not be appropriate for the mucosa-and bone-supported surgical templates that are used in edentulous patients due to their lack of natural teeth. 34 Further investigations are needed to determine whether other alignment reference points (e.g., xation pins and temporary implants) can be used for the digital registration method.…”
Section: Discussionmentioning
confidence: 99%
“…Because dentition constitutes an optical and radiographic marker, alignment was conducted based on the natural teeth. 32,33 This method may not be appropriate for the mucosa-and bone-supported surgical templates that are used in edentulous patients due to their lack of natural teeth. 34 Further investigations are needed to determine whether other alignment reference points (e.g., xation pins and temporary implants) can be used for the digital registration method.…”
Section: Discussionmentioning
confidence: 99%
“…Moreover, small radiopaque objects could be observed in a distorted form on the reconstructed radiographic image in many cases. Image matching largely depends on the outlines of the markers; therefore, the registration accuracy may significantly vary, depending on the numbers, sizes, shapes, and distributions of the markers and different operators 10,17 . In the ES group, the whole surface feature showing a 3D representation of soft tissue was used as the reference region to provide a congruent area for image superimposition.…”
Section: Discussionmentioning
confidence: 99%
“…Three 0.5 mm alignment indexes were made on the facial aspects of right second molar, left central incisor, and left second molar teeth with a round bur to facilitate superimpositions. 20 A third-party SB (Elos Accurate Scan Body, IO 2B-B SA; Elos Medtech) was fixed to the implant analog with a screwdriver (Elos Accurate Screwdriver Manual Short 0.9 Hex; Elos Medtech, Göteborg, Sweden) and tightened with a torque wrench (Nobel Biocare Prosthetic Manual Torque Wrench; Nobel Biocare) at 5 Ncm. MRM was then digitized by using a laboratory scanner (3Shape D2000; 3Shape), 7,[21][22][23][24] which has an accuracy of 5 μm 25 to generate the standard tessellation language (STL) file of the MRM (M0).…”
Section: Methodsmentioning
confidence: 99%