Impact of Oropharyngeal Deposition on Inhaled Dose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0
1

Year Published

2003
2003
2013
2013

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 35 publications
(13 citation statements)
references
References 2 publications
0
12
0
1
Order By: Relevance
“…29 The CI is operated at constant flow rate for testing most types of inhalers. However, for dry powder inhalers (DPIs), the compendial procedures attempt to simulate an inhalation maneuver in order to operate the device so that the powder is aerosolized as a bolus, as would be the case in normal use.…”
Section: Roles In Inhaler Assessmentsmentioning
confidence: 99%
“…29 The CI is operated at constant flow rate for testing most types of inhalers. However, for dry powder inhalers (DPIs), the compendial procedures attempt to simulate an inhalation maneuver in order to operate the device so that the powder is aerosolized as a bolus, as would be the case in normal use.…”
Section: Roles In Inhaler Assessmentsmentioning
confidence: 99%
“…Induction Port (IP): An inlet is required to ensure that the inhaler mouthpiece is oriented with respect to the CI in a fixed horizontal plane, and also to ensure that the aerosol produced is sampled in a defined manner. The IP also serves the purpose of mimicking to a greater or lesser extent depending on its design, the human oropharyngeal region (16). In its role as a model of the entrance to the respiratory tract, the IP collects almost all of the fast moving and so-called ballistic fraction of the inhaler-generated aerosol component of pMDI-produced aerosols formed by flash evaporation of the propellant, and therefore likely to deposit in the oropharynx (16).…”
Section: Contribution To Apsd Measurement Accuracy From Components Ofmentioning
confidence: 99%
“…The IP also serves the purpose of mimicking to a greater or lesser extent depending on its design, the human oropharyngeal region (16). In its role as a model of the entrance to the respiratory tract, the IP collects almost all of the fast moving and so-called ballistic fraction of the inhaler-generated aerosol component of pMDI-produced aerosols formed by flash evaporation of the propellant, and therefore likely to deposit in the oropharynx (16). The pharmacopeial design comprising a straightforward right-angle bend (4,5) is highly simplified both for ease of manufacture and to provide a standardized entry to enable side-byside comparisons of OIP aerosols to be made.…”
Section: Contribution To Apsd Measurement Accuracy From Components Ofmentioning
confidence: 99%
“…In such a manner, the fraction of the dose delivered to the lungs may be estimated. Figure 6 , from Dolovich and Rhem [86] , displays seven different " throats " that have been used for this purpose. Of these, the USP -1, USP -2, and twin impinger inlet have been the most popular [87] .…”
Section: Empirical and Semiempirical Modelsmentioning