2011 IEEE 13th Electronics Packaging Technology Conference 2011
DOI: 10.1109/eptc.2011.6184434
|View full text |Cite
|
Sign up to set email alerts
|

Impact of palladium to the interfacial behavior of palladium coated copper wire on aluminium pad metallization during high temperature storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2012
2012
2025
2025

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 8 publications
1
10
0
Order By: Relevance
“…Considering actual time length of humidity reliability test, Pd is absolute barrier layer to prevent Cu and Al diffusion and then no diffusion means no easily-corroded Cu rich IMC creation. The other experimental results showed thinner IMC growth with Cu-Pd wire than Cu wire [4,10] and more Pd at the surface of FAB showed less growth of Cu/Al IMC [14], which are consistent with our simulation results. Although these experimental IMC growth measurements was done at 175degC HTSL condition, this Pd barrier effect for Cu an Al diffusion should be still valid even at higher temperature.…”
Section: Case 2 Pd Is Only At Surface Case 2-1 Pd Could Behave Barrsupporting
confidence: 95%
See 1 more Smart Citation
“…Considering actual time length of humidity reliability test, Pd is absolute barrier layer to prevent Cu and Al diffusion and then no diffusion means no easily-corroded Cu rich IMC creation. The other experimental results showed thinner IMC growth with Cu-Pd wire than Cu wire [4,10] and more Pd at the surface of FAB showed less growth of Cu/Al IMC [14], which are consistent with our simulation results. Although these experimental IMC growth measurements was done at 175degC HTSL condition, this Pd barrier effect for Cu an Al diffusion should be still valid even at higher temperature.…”
Section: Case 2 Pd Is Only At Surface Case 2-1 Pd Could Behave Barrsupporting
confidence: 95%
“…[1,4,8,10,11,12,13] The Pd distribution in FAB could be decided by Pd-Cu type from different wire supplier and bonding condition. [12,14,15] The mechanism of Pd-Cu wire humidity reliability improvement over bare Cu wire needs to discussed case by case. We explored four different possibilities.…”
Section: Fig 10 Hast Results Comparison Between Cu and Pd-cumentioning
confidence: 99%
“…It has a longer shelf life compared to bare copper wire due to the noble metal coating and is perceived to have better bond reliability under humid conditions [4,9]. Numerous studies on interfacial reaction and IMC formation between Cu and Al bond pads have been carried out [4][5][6][7][8][9][10][11]. It was reported that the IMC phases identified in the Cu/Al bond interface are typically CuAl 2 , CuAl and Cu 9 Al 4 ; the latter two IMCs are mostly found after thermal treatment [10].…”
Section: Introductionmentioning
confidence: 99%
“…However, copper wire is readily oxidized in air and requires the use of forming gas during the ball bonding process [3]. The corrosion susceptibility of Cu wire in humidity reliability tests such as the pressure cooker test (PCT), and the highly accelerated temperature and humidity stress test (HAST), is also a concern and has been widely studied [4][5][6][7]. Copper wire bonds were` reported to have poor reliability performance under PCT and HAST due to the interaction of moisture with chlorine from epoxy mold compounds (EMC) that attack copper in the first bond [8][9].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation