2008
DOI: 10.1016/j.atmosenv.2008.05.051
|View full text |Cite
|
Sign up to set email alerts
|

Impacts of noise barriers on near-road air quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
110
1

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 157 publications
(116 citation statements)
references
References 9 publications
5
110
1
Order By: Relevance
“…Sampling section Distance range (meters) Median reduction (percent) Mean reduction (percent) CO East 0e50 50 46 50e150 31 21 150e300 9 18 West 0e50 45 42 50e150 11 7 150e300 6 5 NO 2 East 0e50 37 37 50e150 41 39 150e300 33 28 West 0e50 34 34 50e150 20 17 150e300 19 11 BC East 0e50 53 43 50e150 63 49 150e300 26 18 West 0e50 57 48 50e150 55 30 150e300 37 24 UFP East 0e50 48 50 50e150 34 44 150e300 16 15 West 0e50 54 66 50e150 27 31 150e300 12 23 wind transport to the highway, which may have blocked upwind pollutant emissions at the barrier wall as reported by Baldauf et al (2008). In addition, emissions from traffic activity along the access road likely contributed to some increase in concentrations in the 0e50 m distance bin as previously described.…”
Section: Pollutantmentioning
confidence: 99%
See 3 more Smart Citations
“…Sampling section Distance range (meters) Median reduction (percent) Mean reduction (percent) CO East 0e50 50 46 50e150 31 21 150e300 9 18 West 0e50 45 42 50e150 11 7 150e300 6 5 NO 2 East 0e50 37 37 50e150 41 39 150e300 33 28 West 0e50 34 34 50e150 20 17 150e300 19 11 BC East 0e50 53 43 50e150 63 49 150e300 26 18 West 0e50 57 48 50e150 55 30 150e300 37 24 UFP East 0e50 48 50 50e150 34 44 150e300 16 15 West 0e50 54 66 50e150 27 31 150e300 12 23 wind transport to the highway, which may have blocked upwind pollutant emissions at the barrier wall as reported by Baldauf et al (2008). In addition, emissions from traffic activity along the access road likely contributed to some increase in concentrations in the 0e50 m distance bin as previously described.…”
Section: Pollutantmentioning
confidence: 99%
“…The earlier studies by Nokes and Benson (1984) and Lidman (1985) showed decreases immediately downwind of the barrier, with this reduction attributed to lofting of the traffic emission plume over the solid structure of the barrier. Later studies (Baldauf et al, 2008;Ning et al, 2010) showed that concentrations behind the barrier generally remained lower than concentrations at a clearing out to several hundred meters, with reductions as high as 50% behind the barrier. The study by Baldauf et al (2008) also showed that noise barriers can increase pollutant concentrations on the upwind side of the wall, and pollutants can meander around the edges of the barrier wall.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Complex (QUIC) flow model coupled with a Lagrangian particle dispersion model to produce 1 concentration patterns that were roughly consistent with observations from Baldauf et al (2008). and dispersion effects induced by a barrier to avoid the computational burden of mechanistic 5 CFD models, which have their own set of parameterizations.…”
Section: Accepted Manuscriptmentioning
confidence: 99%