Impairments in Blood Pressure Regulation and Cardiac Baroreceptor Sensitivity Among Patients With Heart Failure Supported With Continuous-Flow Left Ventricular Assist Devices

Abstract: Background: Continuous-flow (CF) left ventricular assist devices (LVADs) improve outcomes for patients with advanced heart failure (HF). However, the lack of a physiological pulse predisposes to side-effects including uncontrolled blood pressure (BP), and there are little data regarding the impact of CF-LVADs on BP regulation. Methods: Twelve patients (10 males, 60±11 years) with advanced heart failure completed hemodynamic assessment 2.7… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
21
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(21 citation statements)
references
References 50 publications
0
21
0
Order By: Relevance
“…Routinely, pump speed optimisation is based mainly on serial TTEs assessing the degree of LV decompression, RV function and AVO rate in proportion to electrocardiographic QRS complexes 6–8 15 17. Constant AV observation may allow evaluation of the residual LV systolic reserve and match the LVAD speed to metabolic requirements 25.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Routinely, pump speed optimisation is based mainly on serial TTEs assessing the degree of LV decompression, RV function and AVO rate in proportion to electrocardiographic QRS complexes 6–8 15 17. Constant AV observation may allow evaluation of the residual LV systolic reserve and match the LVAD speed to metabolic requirements 25.…”
Section: Discussionmentioning
confidence: 99%
“…The limitation of exercise tolerance in patients with LVAD is multifactorial and results from biventricular HF, inadequate chronotropism, multiorgan dysfunction, pulmonary hypertension, ventilatory inefficiency, anaemia and myopathy 2–6. However, an insufficient rise in cardiac output in response to increased flow demand seems to be one of the most important factors that can potentially be modified 7.…”
Section: Introductionmentioning
confidence: 99%
“…Diastolic BP increases after CF-LVAD implantation, likely because flow through the device is continuous and not gated to the cardiac cycle. 10 This rise in diastolic BP increases MAP. Despite normalization of resting cardiac output, objective measures of functional capacity remain reduced after CF-LVAD implantation.…”
Section: Hemodynamics Of Continuous-flow Ventricular Assist Devicesmentioning
confidence: 97%
“…Despite normalization of resting cardiac output, objective measures of functional capacity remain reduced after CF-LVAD implantation. 10,11 CF-LVADs improve but do not normalize the hyperadrenergic state present in patients with advanced HF and reduced ejection fraction, and cardiac baroreceptor sensitivity remains impaired. 10 Exercise produces large increases in pulsatility from increased ventricular contractility, but BP response is blunted.…”
Section: Bp Regulation In Cf-lvadsmentioning
confidence: 99%
“…A study of cardiopulmonary exercise tests demonstrated an inverse relationship between norepinephrine circulating levels and anaerobic threshold and oxygen pulse, but their levels did not correlate with peak oxygen consumption [ 11 ]. Besides, the exercise-induced increase in blood pressure is blunted in patients with LVAD, despite the increase in the pulsatile component related to the intrinsic ventricular activity [ 12 ]. LVAD-dependent blood flow is only mildly increased during exercise, as current devices cannot adjust flow depending on peripheral requests [ 13 ].…”
Section: Neurohormonal Activationmentioning
confidence: 99%