Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics

Abstract: Impedimetric array in polymer microfluidic cartridge for low cost point-of-care diagnostics, Biosensors and Bioelectronic, https://doi.ABSTRACT Deep Vein Thrombosis and pulmonary embolism (DVT/PE) is one of the most common causes of unexpected death for hospital in-patients. D-dimer is used as a biomarker within blood for the diagnosis of DVT/PE. We report a low-cost microfluidic device with a conveniently biofunctionalised interdigitated electrode (IDE) array and a portable impedimetric reader as a point-of-c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 38 publications
(19 citation statements)
references
References 29 publications
0
19
0
Order By: Relevance
“…There is increasing interest within wearable and flexible electronics for diagnostic applications [ 216 , 217 , 218 ]. There are a wide range of examples, including skin-based sensors for wireless physiological monitoring for neonate and pediatric care [ 219 ], flexible sensors for wound management [ 220 ], DNA analysis using melting curve analysis with an integrated thin film heater [ 221 ], and impedimetric point-of-care diagnostic for selected biomarkers [ 222 ]. Integration of electronic functions can be based on printed organic semiconductor, or inorganic thin films or silicon chip devices which have advantages of functionality, performance, reliability, and power requirements.…”
Section: High Volume Productionmentioning
confidence: 99%
See 2 more Smart Citations
“…There is increasing interest within wearable and flexible electronics for diagnostic applications [ 216 , 217 , 218 ]. There are a wide range of examples, including skin-based sensors for wireless physiological monitoring for neonate and pediatric care [ 219 ], flexible sensors for wound management [ 220 ], DNA analysis using melting curve analysis with an integrated thin film heater [ 221 ], and impedimetric point-of-care diagnostic for selected biomarkers [ 222 ]. Integration of electronic functions can be based on printed organic semiconductor, or inorganic thin films or silicon chip devices which have advantages of functionality, performance, reliability, and power requirements.…”
Section: High Volume Productionmentioning
confidence: 99%
“…Figure 8 A shows semi-additive R2R processes [ 224 ] that can be implemented for patterning of metal on a substrate, and Figure 8 B shows demonstration of producing the electrode layer for impedimetric detection described in [ 222 ] as a R2R process in copper, as a proof of concept. The process incorporates lamination of dry film photoresist, photolithography, development, etching, stripping of photoresist, and laser dicing and has the potential for extension to a wholly R2R manufactured microfluidic device.…”
Section: High Volume Productionmentioning
confidence: 99%
See 1 more Smart Citation
“…This is therefore a very promising approach, although the need for plasma instead of whole blood necessitates pre-analytical centrifugation. Lakey and co-workers reported an impedimetric electrode array within a polymer microfluidic cartridge that demonstrates an approach that could be used for multiplexed sensing of an array of sepsis biomarkers for low-cost point-of-care diagnostics [132].…”
Section: Point-of-care Testing (Poct) For Sepsismentioning
confidence: 99%
“…Impedimetric sensing is also attractive since micro and nanofabrication techniques would allow development of the miniaturised transducers in a convenient manner. The potential of fabricating an impedimetric array in a polymer microfluidic cartridge has been demonstrated as a potential aid for diagnosis of Deep Vein Thrombosis/Pulmonary Embolism (DVT/PE) and towards low cost point-of-care diagnostics [17] An impedimetric array within a microfluidic cartridge could allow multiple measurements of a single biomarker or alternatively measurements of multiple biomarkers within the same microfluidic cartridge.…”
Section: Developments Towards Portable Diagnosticsmentioning
confidence: 99%