2006
DOI: 10.1016/j.exer.2005.07.007
|View full text |Cite
|
Sign up to set email alerts
|

Implantation and testing of subretinal film electrodes in domestic pigs

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
22
0
1

Year Published

2006
2006
2011
2011

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(23 citation statements)
references
References 41 publications
0
22
0
1
Order By: Relevance
“…The species involved include rats (n=6) [26,29,76,80,81,96], rabbits (n=14) [33,36,42,72,73,90,94,95,102,103,105,106,116,121], cats (n=18) [18, 19, 21-23, 30, 32, 43, 78, 79, 82, 93, 98, 99, 101, 114, 117, 120], dogs (n=4) [16,39,40,66], sheep (n=1) [51] and pigs/minipigs (n=9) [34,42,49,59,69,91,92,100,102]. Two papers [16,26] which involved three animal species do not figure in Table 2 due to lack of space, but are discussed in the review.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The species involved include rats (n=6) [26,29,76,80,81,96], rabbits (n=14) [33,36,42,72,73,90,94,95,102,103,105,106,116,121], cats (n=18) [18, 19, 21-23, 30, 32, 43, 78, 79, 82, 93, 98, 99, 101, 114, 117, 120], dogs (n=4) [16,39,40,66], sheep (n=1) [51] and pigs/minipigs (n=9) [34,42,49,59,69,91,92,100,102]. Two papers [16,26] which involved three animal species do not figure in Table 2 due to lack of space, but are discussed in the review.…”
Section: Resultsmentioning
confidence: 99%
“…Furthermore, as Schanze and colleagues point out, there is much less accumulated knowledge about the visual system of pigs relative to that of cats [100]. Notwithstanding these limitations, minipigs and pigs have featured extensively in prosthesis research.…”
Section: Pig/minipigmentioning
confidence: 99%
See 1 more Smart Citation
“…Nevertheless, in up to 50% of all experiments no cortical potentials could be recorded, presumably due to contact problems. After improving the system and additional development of film electrodes [17], the team inserted subretinal implants into several patients and was able to achieve visual perceptions in some cases, i.e. in scanning laser ophthalmoscope microperimetry and lately even in visual acuity determined by the Landolt C test [18,19].…”
Section: Subretinal Implantsmentioning
confidence: 99%
“…Thanks to progress made in the fields of microtechnology and microsurgery, different approaches emerge, particularly those where stimulation of the retina is performed. This may be done via epiretinal, subretinal or transscleral electrodes [2][3][4][5][6][7][8] . It was hypothesized that electric stimulation of the innermost retinal…”
mentioning