2021
DOI: 10.1109/tpel.2020.3042639
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of a Novel Very Low Frequency Cosine-Rectangular Voltage Generator for Insulation Testing of Power Cables

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…(23) where U m (ω) is the PD measured signal, H CAB (ω) is the transfer function of the cable that the PD signal propagated through, H PDC (ω) and H M (ω) are the transfer functions of the PD coupler and the measurement system. H CAB (ω) can be obtained from Equations ( 11) and (12).…”
Section: Ifdm Reconstruction Processmentioning
confidence: 99%
See 1 more Smart Citation
“…(23) where U m (ω) is the PD measured signal, H CAB (ω) is the transfer function of the cable that the PD signal propagated through, H PDC (ω) and H M (ω) are the transfer functions of the PD coupler and the measurement system. H CAB (ω) can be obtained from Equations ( 11) and (12).…”
Section: Ifdm Reconstruction Processmentioning
confidence: 99%
“…The damped AC (DAC) voltage PD test system is commercialized and applied successfully [9][10][11]. Some researchers tried to use very low frequency voltage to test PD signals [12,13]. After the PD signals are excited and captured, the PD is always localized using the time domain reflectometry (TDR) method [14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…The dielectric loss factor (tangent delta, Tan δ) is a common used parameter to estimate the bulk aging condition of the XLPE insulation. Tan δ is usually obtained under a very low frequency (VLF) high voltage, typically at a 0.1Hz sinusoidal voltage, though there may be some other types of waveform, such as square wave, cosine-rectangular wave [8][9][10][11]. The Tan δ values at different time, of different phases and under different voltages are adopted to evaluate the degradation of cable insulation.…”
Section: Introductionmentioning
confidence: 99%
“…The voltage withstand test is a method used to detect cable insulation or connection defects. This method is destructive and for a long connection the test power source can be an issue [6]. The tan δ measurement can be used to evaluate the overall deterioration of the insulation.…”
Section: Introductionmentioning
confidence: 99%