2019
DOI: 10.1007/s40031-019-00417-9
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of MVF-Based Control Technique for 3-Φ Distribution Static Compensator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 19 publications
0
4
0
Order By: Relevance
“…For each switching state, the values of i ca (k + 1), i cb (k + 1), and i cb (k + 1) are determined using (10) and calculate the cost function value using (11). Among the available switching states, the state which gives the minimum value of C is applied for the next sampling to achieve proper control of FL-DSTATCOM.…”
Section: Conventional Predictive Model Of Fl-dstatcommentioning
confidence: 99%
See 2 more Smart Citations
“…For each switching state, the values of i ca (k + 1), i cb (k + 1), and i cb (k + 1) are determined using (10) and calculate the cost function value using (11). Among the available switching states, the state which gives the minimum value of C is applied for the next sampling to achieve proper control of FL-DSTATCOM.…”
Section: Conventional Predictive Model Of Fl-dstatcommentioning
confidence: 99%
“…Distribution static compensator (DSTATCOM) is a shunt connected CPD, which is mainly dedicated to address current related power quality issues [3,4]. Among the available DSTATCOM topologies, three H-bridge (HB), three-leg voltage source inverter (VSI), three-phase splitcapacitor (TPSC), four-leg DSTATCOM (FL-DSTATCOM) and multi-level inverter (MLI) topologies are treated as traditional topologies [5][6][7][8][9][10]. Three single-phase HB inverters are used to implement a three HB DSTATCOM, which can be applicable to both three-phase three wire (3P3W) and three-phase four wire (3P4W) systems.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Alternatively, the problem of DC offsets and harmonics alleviation can be resolved by utilizing the PSCs information derived from the CCP voltages. The utilization of the MVF, which has a dual architecture within αβ frames, is employed for obtaining PSCs of the grid voltage necessary for synchronization [13]. An additional concern pertains to the existence of DC offsets in the CCP voltages, resulting in the appearance of DC offsets in PSCs obtained by dual architectures.…”
Section: Introductionmentioning