2021
DOI: 10.1007/s00405-021-06924-0
|View full text |Cite
|
Sign up to set email alerts
|

Implementation of secondary reconstructions of flat-panel volume computed tomography (fpVCT) and otological planning software for anatomically based cochlear implantation

Abstract: Purpose For further improvements in cochlear implantation, the measurement of the cochlear duct length (CDL) and the determination of the electrode contact position (ECP) are increasingly in the focus of clinical research. Usually, these items were investigated by multislice computed tomography (MSCT). The determination of ECP was only possible by research programs so far. Flat-panel volume computed tomography (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for high spatial resolution… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
9
0
3

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(16 citation statements)
references
References 44 publications
(78 reference statements)
0
9
0
3
Order By: Relevance
“…But in clinical imaging, there is a dependence of the CDL on the resolution. The CDL measured in flat‐panel volume CT (resolution, 100 µm) resulted in a significantly longer CDL when compared with standard flat‐panel volume CT (460 µm) and CT (600 µm) 34 . Furthermore, there was a tendency toward a longer CDL in CT data sets with higher resolution 35 .…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…But in clinical imaging, there is a dependence of the CDL on the resolution. The CDL measured in flat‐panel volume CT (resolution, 100 µm) resulted in a significantly longer CDL when compared with standard flat‐panel volume CT (460 µm) and CT (600 µm) 34 . Furthermore, there was a tendency toward a longer CDL in CT data sets with higher resolution 35 .…”
Section: Discussionmentioning
confidence: 90%
“…The CDL measured in flat-panel volume CT (resolution, 100 mm) resulted in a significantly longer CDL when compared with standard flat-panel volume CT (460 mm) and CT (600 mm). 34 Furthermore, there was a tendency toward a longer CDL in CT data sets with higher resolution. 35 To exclude the variability of the resolution, the slice thickness was set to 600 mm for both MRI and CT in the present study.…”
Section: Discussionmentioning
confidence: 98%
“…So ergeben sich in der Synchrotron-Phasenkontrast-Bildgebung (SR-PCI), der aktuell höchstauflösenden Methode, Werte für die CDL OC von 32,1 mm und CDL LW von 39,0 mm [ 20 ]. Messungen anhand von Flachdetektor-Volumen- Computertomographien (fpVCT) zeigen eine CDL OC von 34,63 ± 1,47 mm [ 27 ]. Die CDL OC ist dabei in Zusammenhang mit der Greenwood-Funktion für die Frequenzbestimmung von zentraler Bedeutung [ 16 ].…”
Section: Hintergrundunclassified
“…Dazu sind fpVCT in der postoperativen Lagekontrolle weniger artefaktanfällig [ 19 ]. Optimale Messbedingungen können sich dabei aus einer Kombination aus sekundär rekonstruierten fpVCT und der Nutzung der Software OTOPLAN ergeben [ 27 ]. Die MRT erfolgt zum Ausschluss einer retrocochleären Pathologie, der Beurteilung des Hörnervs und der Flüssigkeitsfüllung der Cochlea sowie zur Detektion bindegewebiger Obliterationen und früher Stadien der Ossifikation [ 38 ].…”
Section: Hintergrundunclassified
“…2b).Postoperatives ProzedereDie postoperativ durchgeführte radiologische Lagekontrolle kann auch dazu genutzt werden, die Cochlea zu vermessen und die CDL zu berechnen. Untersuchungen haben gezeigt, dass eine höher auflösende Bildgebung hierfür insbesondere bei einliegender Elektrode von Vorteil ist und die cochleären Parameter trotz möglicher Artefakte weniger verfälscht werden[28,35].Aus den CDL-Berechnungen kann dann die Lage jedes Elektrodenkontakts individuell bestimmt und eine 3-dimensionale Darstellung der inserierten Elektrode erreicht werden (▶ Abb. 4).…”
unclassified