Implementation of TomoEDGE in the independent dose calculator CheckTomo

Abstract: PurposeCheckTomo is an independent dose calculation software for tomotherapy. Recently, Accuray (Accuray Inc., Sunnyvale, CA, USA) released an upgrade of its tomotherapy treatment device, called TomoEDGE Dynamic Jaws, which improves the quality of treatment plans by enhancing the dose delivery with the help of jaws motion. This study describes the upgrade of CheckTomo to that new feature.MethodsTo account for the varying width and off‐axis shift of dynamic jaws fields, the calculation engine of CheckTomo multi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…63 Due to the uniqueness and complexity of tomotherapy delivery, most IDC software for conventional linacs are incompatible with tomotherapy. Even though not recommended by TG 148, some clinics have developed their own correction-based, [88][89][90][91] model-based, 92 or Monte Carlo-based 69,[93][94][95][96][97] algorithms for tomotherapy IDCs. While these algorithms demonstrated success in some clinics, most clinics still lack the means to incorporate tomotherapy IDC into their plan check process.…”
Section: Independent Dose Calculationmentioning
confidence: 99%
“…63 Due to the uniqueness and complexity of tomotherapy delivery, most IDC software for conventional linacs are incompatible with tomotherapy. Even though not recommended by TG 148, some clinics have developed their own correction-based, [88][89][90][91] model-based, 92 or Monte Carlo-based 69,[93][94][95][96][97] algorithms for tomotherapy IDCs. While these algorithms demonstrated success in some clinics, most clinics still lack the means to incorporate tomotherapy IDC into their plan check process.…”
Section: Independent Dose Calculationmentioning
confidence: 99%
“…In TomoTherapy machines without TomoEDGE option, treatment was delivered by static jaws at fixed field width, either 10, 25, or 50 mm at isocenter during the entire treatment. Thus, the field penumbra along the longitudinal direction was approximately identical to the field size on both cranial‐caudal sides of the target volume 1 . Further to this beam characteristic, it is essential to limit the dose to organ at risk (OAR) by delivering the treatment with MLC collimated sub‐fields under the drawback of increasing treatment time.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the field penumbra along the longitudinal direction was approximately identical to the field size on both cranial‐caudal sides of the target volume. 1 Further to this beam characteristic, it is essential to limit the dose to organ at risk (OAR) by delivering the treatment with MLC collimated sub‐fields under the drawback of increasing treatment time.…”
Section: Introductionmentioning
confidence: 99%