2017
DOI: 10.1128/jcm.02128-16
|View full text |Cite
|
Sign up to set email alerts
|

Improved Accuracy of Cefepime Susceptibility Testing for Extended-Spectrum-Beta-Lactamase-Producing Enterobacteriaceae with an On-Demand Digital Dispensing Method

Abstract: Extended-spectrum beta-lactamase (ESBL)-producing Enterobacteriaceae generally cannot be treated with penicillins and cephalosporins. However, some later-generation cephalosporins, including cefepime, are poorly hydrolyzed by specific ESBL enzymes, and certain strains demonstrate in vitro susceptibility to these agents, potentially affording additional treatment opportunities. Moreover, the ability to adjust both the dose and dosing interval of beta-lactam agents allows the treatment of strains with elevated M… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
17
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
8

Relationship

4
4

Authors

Journals

citations
Cited by 17 publications
(19 citation statements)
references
References 29 publications
2
17
0
Order By: Relevance
“…Checkerboard array testing. To create checkerboard arrays, serial 2-fold dilutions of 2 antibiotics were dispensed in orthogonal titrations by the D300 instrument using the DDM previously developed by our group (17,47,52). Titrations consisted of 11 2-fold dilutions of colistin (0.016 to 16 g/ml) and 13 2-fold dilutions of all other antibiotics.…”
Section: Methodsmentioning
confidence: 99%
“…Checkerboard array testing. To create checkerboard arrays, serial 2-fold dilutions of 2 antibiotics were dispensed in orthogonal titrations by the D300 instrument using the DDM previously developed by our group (17,47,52). Titrations consisted of 11 2-fold dilutions of colistin (0.016 to 16 g/ml) and 13 2-fold dilutions of all other antibiotics.…”
Section: Methodsmentioning
confidence: 99%
“…9 We previously determined through extensive analysis that polysorbate-20 at the concentrations used in assay wells has no effect on MIC determinations for all antibiotics examined. 5, 10 …”
Section: Methodsmentioning
confidence: 99%
“…1 BMD experiments were performed in triplicate for each antibiotic/organism combination with the modal result recorded as the reference MIC. 5 …”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The availability of automated liquid handlers and other programmable antibiotic dispensing systems means that the previously time-consuming and error-prone process of preparing subdoubling dilutions is no longer a true impediment. Finer dilutions could be discontinuous and concentrate around critical decision points, such as cutoffs bordering safety margins and breakpoints, and could include finer gradations bracketing quality control strain ranges to allow greater sensitivity to detect subtle drift in panel performance (25,26). While decreasing dilution intervals will not reduce the biological variability that may play a role in inconsistent MIC results, it will provide increased data about the true location of the MIC within the dilution series.…”
mentioning