Improved Algorithm for Automated Glucose Clamps

Abstract: With the improved algorithm, all experiments confirmed a reduction in BG- and GIR-oscillations without a major impact on other glucose clamp parameters. The optimized algorithm has been implemented in ClampArt for all future glucose clamp studies.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 6 publications
0
6
0
Order By: Relevance
“…Particle swarm algorithms are essentially a type of evolutionary algorithm. Because the algorithm has the characteristics of fast convergence speed and simple coding implementation, it has been widely used in engineering applications and other fields, and has become one of the hot directions in the field of intelligent computing research [ 20 ].…”
Section: Improved Algorithms and Related Methodsmentioning
confidence: 99%
“…Particle swarm algorithms are essentially a type of evolutionary algorithm. Because the algorithm has the characteristics of fast convergence speed and simple coding implementation, it has been widely used in engineering applications and other fields, and has become one of the hot directions in the field of intelligent computing research [ 20 ].…”
Section: Improved Algorithms and Related Methodsmentioning
confidence: 99%
“…Hence, it is important to present data on clamp quality such as control deviation (mean deviation from the target BG level) and precision (BG fluctuation from the clamp). 15 In our studies, data was derived from two automated clamps, Biostator and ClampArt and while the latter is a more modern device with some advantages, 16 clamp quality was acceptable and most importantly comparable between the treatments in all studies, even when including the low responders. Nevertheless, it is important to investigate the impact of clamps with low GIR response and BG elevations on the overall study outcome.…”
Section: Discussionmentioning
confidence: 99%
“…During the performance of a euglycemic clamp evaluating the PK/ PD of a long-acting insulin analog, exogenous glucose infusion was frequently and properly adjusted according to the BG to ensure good quality (Heise et al, 2016;Kuhlenkotter et al, 2017;Benesch et al, 2022). Blood insulin concentration over time (PK) always predicts insulin action; in return, the GIR over time reflects the clinical glucose-lowering effect.…”
Section: Discussionmentioning
confidence: 99%