2009 Annual International Conference of the IEEE Engineering in Medicine and Biology Society 2009
DOI: 10.1109/iembs.2009.5333465
|View full text |Cite
|
Sign up to set email alerts
|

Improved diagnostics through quantitative ultrasound imaging

Abstract: Conventional B-mode imaging in ultrasound consists of displaying the log-compressed envelope of the backscattered signal. While clinical ultrasonic B-mode images have good spatial resolution, i.e., better than a millimeter, the contrast resolution of ultrasonic B-mode images is typically low. However, additional information is contained in the ultrasonic backscattered signal, which can be used to create images related to tissue microstructure. Because diagnosis of disease is typically based on histological exa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 15 publications
0
11
0
Order By: Relevance
“…Nevertheless, in a recent study, the HK distribution was used in conjunction with computationally-extensive algorithms to characterize cardiac tissues (Hao et al, 2002). More recently, a new parameter-estimation algorithm for the HK distribution was developed that is efficient and robust (Hruska et al, 2009; Hruska and Oelze, 2009). This improved parameter-estimation algorithm provides more accurate information to elucidate better the relationships between the envelope statistics and the underlying structures responsible for the signals.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, in a recent study, the HK distribution was used in conjunction with computationally-extensive algorithms to characterize cardiac tissues (Hao et al, 2002). More recently, a new parameter-estimation algorithm for the HK distribution was developed that is efficient and robust (Hruska et al, 2009; Hruska and Oelze, 2009). This improved parameter-estimation algorithm provides more accurate information to elucidate better the relationships between the envelope statistics and the underlying structures responsible for the signals.…”
Section: Introductionmentioning
confidence: 99%
“…Quantitative ultrasound (QUS) parameters such as the attenuation slope, sound speed, backscatter coefficient, effective scatterer diameter, and spacing have been investigated in order to evaluate the pathological state of tissue. [1][2][3][4][5] The ability to estimate the attenuation slope accurately is important for the estimation of many of the other QUS parameters. In addition, the attenuation slope may provide a direct correlation to diagnostic approaches that are used for clinical diagnosis currently.…”
Section: Introductionmentioning
confidence: 99%
“…The BSC has been used to characterize tissue microstructures in ocular, myocardial, liver and kidney tissues (Insana et al 1992;Lizzi et al 1983Lizzi et al , 1987Wear 1987). Additionally, maps of the spatial distribution of the BSC were used to monitor high-intensity focused ultrasound (HIFU) treatments (Kemmerer et al 2010), detect abnormal lymph nodes (Mamou et al 2011), differentiate between cancer tissues (Hruska et al 2009;Oelze et al 2004) and identify various forms of cell death (Kolios et al 2002(Kolios et al , 2003. In some cases, the BSC could not be used to identify breast cancers, although the optical images displayed a clear difference in the cellular microstructure (Oelze and Zachary 2006).…”
Section: Introductionmentioning
confidence: 99%