Improved MALDI‐MS method for the highly sensitive and reproducible detection of biomarker peaks for the proteotyping of Salmonella serotypes

Abstract: The rapid identification and classification of pathogenic microorganisms, including Salmonella enterica, is important for the surveillance and prevention of foodborne diseases. Matrix‐assisted laser desorption\ionization time‐of‐flight mass spectrometry (MALDI‐TOFMS) has been shown to be an effective tool for the rapid identification of microorganisms. In a previous report, a mass database consisting of 12 biomarker proteins, S8, L15, L17, L21, L25, S7, superoxide dismutase (SodA), peptidylprolyl cis‐trans iso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…As for the three strains doubly hitting the correct and the other groups with the same score of 7, adding a new biomarker to the database could help with accurate identification. However, at present, since we have not found any biomarkers other than Table 3 that can be detected stably, the sample preparation method may need to be improved, as examined for Salmonella enterica [ 34 ].…”
Section: Discussionmentioning
confidence: 99%
“…As for the three strains doubly hitting the correct and the other groups with the same score of 7, adding a new biomarker to the database could help with accurate identification. However, at present, since we have not found any biomarkers other than Table 3 that can be detected stably, the sample preparation method may need to be improved, as examined for Salmonella enterica [ 34 ].…”
Section: Discussionmentioning
confidence: 99%
“…Recently, MALDI-TOF MS has been commonly used as a routine identification method [ 5 , 6 ]. However, there are a few previous reports on the performance of VITEK MS in identifying Salmonella [ 11 , 12 , 13 ]. Guo et al [ 17 ] using 1025 bacteria isolated from clinical specimens, reported that VITEK MS exhibited good performance; however, only two strains of Salmonella were included in the report.…”
Section: Discussionmentioning
confidence: 99%
“…The performance of VITEK MS in identifying bacteria, fungi, and mycobacteria has been steadily evaluated [ 6 , 7 , 8 , 9 , 10 ]. However, only a few studies have evaluated the performance of VITEK MS in identifying Salmonella strains and serotypes [ 11 , 12 , 13 ]. This study aimed to evaluate the usefulness of MALDI-TOF VITEK MS for Salmonella identification using more than 1000 Salmonella strains, including 60 serotypes, isolated from human specimens.…”
Section: Introductionmentioning
confidence: 99%
“…The improved mass spectrometry approach for the absolute detection of biomarkers from Salmonella serotypes was introduced by Fukuyama and colleagues ( 116 ). In a cohort research, quantitative proteomics was used to uncover distinct biomarkers in the plasma of individuals with active tuberculosis.…”
Section: Identification Of Diagnostic Markersmentioning
confidence: 99%