Improved Sensitivity for Methotrexate Analysis Using Enzyme Multiplied Immunoassay Technique on the Siemens Viva-E Instrument

Abstract: The described modifications have enhanced the sensitivity of the Syva EMIT assay for MTX measurements down to 0.05 μmole/L with acceptable precision that can be used in clinical practice for monitoring MTX therapy.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
12
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(14 citation statements)
references
References 6 publications
2
12
0
Order By: Relevance
“…Fluorescence polarization immunoassay (FPIA) is the most widespread method for MTX determination [2]. However, FPIA is gradually disappearing and alternative assays [3,4] are gaining a market share. ARK™ MTX Immunoassay is a homogeneous immunoassay intended for the quantitative determination of MTX in human serum or plasma on automated clinical chemistry analyzers.…”
mentioning
confidence: 99%
“…Fluorescence polarization immunoassay (FPIA) is the most widespread method for MTX determination [2]. However, FPIA is gradually disappearing and alternative assays [3,4] are gaining a market share. ARK™ MTX Immunoassay is a homogeneous immunoassay intended for the quantitative determination of MTX in human serum or plasma on automated clinical chemistry analyzers.…”
mentioning
confidence: 99%
“…The linearity obtained in our study was higher compared to that obtained by Borgman et al . [ 3 ] on Siemens Viva-E instrument. However, it was much lower compared to the lower limit of 0.3 μMol/L claimed by the kit manufacturer.…”
mentioning
confidence: 99%
“…Bouquie et al CMIA/FPIA but with application on TDx. They also observed an overestimation with EMIT as other authors 21,22 and discussed the role of the metabolite DAMPA. Since the imprecision of real samples was poorer than that of QC samples both in our and in published studies, the influence of endogen compounds and matrix effect may also be of importance despite the use of buffer in all assays.…”
Section: Discussionmentioning
confidence: 52%
“…18 poorer imprecisions than those obtained in previously published results with ARK on Cobas c502, that itself had poorer imprecisions than MTX-ARCHI. 17 Several authors compared assays for MTX determination vs TDX or mass spectrometry 10,16,17,[19][20][21] but no recent comparison was performed with HPLC method. The maximal and minimal systematic bias (-0.075 and 0.002 mM) were observed for MTX-TDX and MTX-ARCHI, respectively, below 0.1 mM in accord with bias criteria.…”
Section: Discussionmentioning
confidence: 99%