Improved technique for implanting electromagnetic flowmeter probes on the coronary artery.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
9
0

Year Published

1974
1974
1989
1989

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 18 publications
(9 citation statements)
references
References 0 publications
0
9
0
Order By: Relevance
“…A 2.5-to 3.5-mm Howell ST-type electromagnetic flowmeter probe (Howell Instruments, Camarillo, Calif.) and a pneumatic occluder were positioned on the proximal left circumflex coronary artery (12). The proximal end of the catheters, the occluder, and the leads to the electromagnetic flowmeter probe were tunneled to the base of the neck and placed in a subcutaneous pouch.…”
Section: Methodsmentioning
confidence: 99%
“…A 2.5-to 3.5-mm Howell ST-type electromagnetic flowmeter probe (Howell Instruments, Camarillo, Calif.) and a pneumatic occluder were positioned on the proximal left circumflex coronary artery (12). The proximal end of the catheters, the occluder, and the leads to the electromagnetic flowmeter probe were tunneled to the base of the neck and placed in a subcutaneous pouch.…”
Section: Methodsmentioning
confidence: 99%
“…Care was taken to attain mechanical stability of the flow probe on the coronary artery to ensure a consistently stable baseline during later coronary flow measurements. 6 An inflatable cuff-type hydraulic occluder constructed in our laboratory of polyvinyl chloride tubing (o.d., 2.7 mm) was placed around the circumflex coronary artery distal to the electromagnetic flowmeter probe.…”
Section: Methodsmentioning
confidence: 99%
“…Care was taken to attain mechanical stability of the flow probe on the coronary artery to ensure a consistently stable baseline during later coronary flow measurements. 6 An inflatable cuff-type hydraulic occluder constructed in our laboratory of polyvinyl chloride tubing (o.d., 2.7 mm) was placed around the circumflex coronary artery distal to the electromagnetic flowmeter probe.7 Injection of water into the occluder tubing with a tuberculin syringe allowed precisely controlled partial inflation of the occluder to cause reproducible restriction of coronary artery inflow. The electromagnetic flowmeter leads, aortic and left atrial catheters, and hydraulic occluder tube were tunneled dorsally into a subcutaneous pouch at the base of the neck but were not exteriorized to protect them from damage.…”
mentioning
confidence: 99%
“…In this situation, during the interval when coronary flow was restricted to the preocclusion control level considerable capacity to increase oxygen extraction would exist and the blood flow debt might, at least in part, have been repaid by increasing oxygen extraction without need for further increase of coronary blood flow. In man, nitroglycerin has been demonstrated to decrease left ventricular volume secondary to reduction of arterial pressure as well as to decreased venous return resulting from systemic venodilation (10,20). Reduction of left ventricular volume would result in decreased left ventricular systolic tension development, a major determinant of myocardial oxygen consumption (21).…”
Section: Effects Of Nitroglycerin On Transmural Myocardial Blood Flowmentioning
confidence: 99%