2010
DOI: 10.1016/j.jse.2009.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Improved time-zero biomechanical properties using poly-L-lactic acid graft augmentation in a cadaveric rotator cuff repair model

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

3
48
0
1

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
2

Relationship

2
4

Authors

Journals

citations
Cited by 68 publications
(52 citation statements)
references
References 45 publications
3
48
0
1
Order By: Relevance
“…2 For the cadaveric rotator cuff repairs, a strip of the superior infraspinatus tendon (12 mm wide) was released and repaired to the greater tuberosity using a double-row transosseous technique with 2 Mason Allen sutures per row. 20 The prototypical augmen tation graft used for the augmented repairs was a poly-L-lactic acid (PLLA) scaffold (X-Repair, Synthasome Inc, San Diego, CA, USA). The nonaugmented repair was modeled as 2 springs in series (Fig.1, A and B), and the augmented repair was modeled as a combination of 5 springs in series and parallel (Fig.…”
Section: Methodsmentioning
confidence: 99%
See 4 more Smart Citations
“…2 For the cadaveric rotator cuff repairs, a strip of the superior infraspinatus tendon (12 mm wide) was released and repaired to the greater tuberosity using a double-row transosseous technique with 2 Mason Allen sutures per row. 20 The prototypical augmen tation graft used for the augmented repairs was a poly-L-lactic acid (PLLA) scaffold (X-Repair, Synthasome Inc, San Diego, CA, USA). The nonaugmented repair was modeled as 2 springs in series (Fig.1, A and B), and the augmented repair was modeled as a combination of 5 springs in series and parallel (Fig.…”
Section: Methodsmentioning
confidence: 99%
“…The aggregate spring-network models were validated by comparing the model predictions to in vitro experi mental data in the failure-loading region of repair constructs that were preconditioned for 100 cycles from 50 to 150 N at 0.25 Hz and subsequently distracted to failure with uniaxial loading in tension at 30 mm/min. 20 Further details of the model and its validation have previously been described. 2 In the current study, the validated models were varied para metrically to simulate clinically relevant scenarios, namely, changes in tendon quality, altered surgical technique(s) and different scaffold designs.…”
Section: Methodsmentioning
confidence: 99%
See 3 more Smart Citations