2020
DOI: 10.1109/tia.2019.2960732
|View full text |Cite
|
Sign up to set email alerts
|

Improved Widrow–Hoff Based Adaptive Control of Multiobjective PV-DSTATCOM System

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…The accuracy of the MVF-DEANF-PLL methodology is clear, as the utility current's (i sabc ) THD remained below the limitations of the IEEE-519 standard [25]. The laboratory arrangement of the SPVS with Widrow Hoff control exhibited a THD of around 4.06% in the utility current, as documented in the available literature [28]. The effectiveness of the proposed control in PQ issue alleviation exceeds that of the Widrow Hoff control.…”
Section: Response At Spv Hoursmentioning
confidence: 97%
See 1 more Smart Citation
“…The accuracy of the MVF-DEANF-PLL methodology is clear, as the utility current's (i sabc ) THD remained below the limitations of the IEEE-519 standard [25]. The laboratory arrangement of the SPVS with Widrow Hoff control exhibited a THD of around 4.06% in the utility current, as documented in the available literature [28]. The effectiveness of the proposed control in PQ issue alleviation exceeds that of the Widrow Hoff control.…”
Section: Response At Spv Hoursmentioning
confidence: 97%
“…Moreover, the methodology being proposed in this study guarantees that the THD of the current 𝑖 remains below the prescribed limitations established by the IEEE-519 standard [25]. In the traditional integrated LMS-LMF control, it was noted that the supply current had a THD of 2.48% [28].…”
Section: System Response At Non-spv Hoursmentioning
confidence: 99%
“…Continuing this trajectory, a comprehensive literature review has been conducted on the current state-of-the-art techniques for SPV-integrated DSTATCOM. In [6], a photovoltaic DSTATCOM (PV-DSTATCOM) system is presented, extracting maximum power from PV for supplying the functional load and directing excess power to the grid. The control of the voltage-source converter (VSC) in this approach is achieved by generating load current fundamental components, synchronizing, and enhancing PQ using the same algorithm.…”
Section: ░ 1 Introductionmentioning
confidence: 99%
“…In [9], a variable stepsize adaptive neuron technique is introduced to mitigate steadystate and dynamic errors observed in previous methods in the literature. Moreover, in these methods [6]- [9], the PV array is connected to the boost converter before being linked to the VSC's dc-link. This configuration contributes to increased control complexity and overall cost [10].…”
Section: ░ 1 Introductionmentioning
confidence: 99%
“…In [6], a multifunctional three phase solar energy conversion system is proposed, which has the capability to compensate the PQ issues in load side. A Distribution Static Compensator (DSTATCOM) based shunt active filtering in addition to clean energy generation is proposed in [7], [8]. The benefit of excellent load voltage regulation by DSTATCOM comes at the cost of reactive power injection.…”
Section: Introductionmentioning
confidence: 99%