2021
DOI: 10.3390/en14041200
|View full text |Cite
|
Sign up to set email alerts
|

Improvement Effect of Green Remodeling and Building Value Assessment Criteria for Aging Public Buildings

Abstract: The Green Remodeling Project under South Korea’s Green New Deal policy is a government-led project intended to strengthen the performance sector directly correlated with energy performance among various elements of improvement applicable to building remodeling by replacing insulation materials, introducing new and renewable energy, introducing high-efficiency equipment, etc., with public buildings taking the lead in green remodeling in order to induce energy efficiency enhancement in private buildings. However… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 8 publications
1
4
0
Order By: Relevance
“…The difference between the ELA@30 Pa means was insignificant at 2.336 cm 2 . In addition, the standard error of the proposed method was 0.435 cm 2 , which is similar to the standard error of the blower door test at 0.276 cm 2 .…”
Section: Experimental Results In Case Bsupporting
confidence: 70%
See 2 more Smart Citations
“…The difference between the ELA@30 Pa means was insignificant at 2.336 cm 2 . In addition, the standard error of the proposed method was 0.435 cm 2 , which is similar to the standard error of the blower door test at 0.276 cm 2 .…”
Section: Experimental Results In Case Bsupporting
confidence: 70%
“…This transient method yielded a mean ELA@30 Pa of 72.899 cm 2 , which differed only slightly by 3.32% from the conventional measurement method. Figure 4b displays the average ELA@30 Pa for the blower door test, which was 83.345 cm 2 , along with the associated standard deviation and standard error values of 0.603 cm 2 and 0.269 cm 2 , respectively. The transient method yielded an average ELA@30 Pa of 81.233 cm 2 , with an associated standard deviation and standard error values of 0.834 cm 2 and 0.373 cm 2 , respectively.…”
Section: Experimental Results In Case Bmentioning
confidence: 99%
See 1 more Smart Citation
“…Additionally, Gabrielli et al analyzed sources of uncertainty and risk management techniques in the context of sustainable real estate development, particularly focusing on energy efficiency improvements in Northern Italy using Monte Carlo and sensitivity analysis methods [28]. Furthermore, researchers in South Korea conducted various studies to promote green remodeling projects, but most of them focused on the effect of improving the energy performance of existing old buildings [29][30][31][32].…”
Section: Introduction 1background and Objectives Of The Studymentioning
confidence: 99%
“…At the same time, we cannot ignore the valuable industrial relics and blindly demolish them under the guidance of the city's economic interests (Li et al 2021). In previous studies on the restoration value of industrial relics, most of them had generalized discussions on the restoration value of industrial buildings (Liu et al 2018;Bottero et al 2019;Wu 2021) and analyzed and evaluated the value of industrial buildings from a single aspect (Gao 2008) and the application of value evaluation in other countries or fields (Jun et al 2021), such as railway heritage (Pan et al 2019), water conservancy engineering (Rong et al 2006), and port shoreline(Yang and Zhang 2012).…”
Section: Introductionmentioning
confidence: 99%