19th International Congress of Metrology (CIM2019) 2019
DOI: 10.1051/metrology/201927009
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of dynamic pressure standard for calibration of dynamic pressure transducers

Abstract: In dynamic pressure measurement phenomena, dynamic pressure calibration of the measurement chain including a pressure sensor, signal conditioning amplifier and data acquisition part is required. A drop mass dynamic calibration machine which is used for the dynamic calibration in hydraulic media was designed and developed. This study presents a research study and measurement results on the dynamic calibration of pressure transducers by using the newly developed machine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…[66] We calibrate the frequency and time responses of the sensor against periodic and aperiodic pressure waves (e.g., a step signal), respectively. [67] Generation of these types of signals requires designated devices, such as shock tubes, [68] fast-opening valves, [68,69] and modulated weight or volume systems [69,70] In the calibration process of frequency response, sampling rate should follow the Nyquist theorem to avoid signal aliasing, and frequencies induced by the calibration setup itself could be excluded beforehand, for example, using Helmholtz resonance theory.…”
Section: Calibration Proceduresmentioning
confidence: 99%
“…[66] We calibrate the frequency and time responses of the sensor against periodic and aperiodic pressure waves (e.g., a step signal), respectively. [67] Generation of these types of signals requires designated devices, such as shock tubes, [68] fast-opening valves, [68,69] and modulated weight or volume systems [69,70] In the calibration process of frequency response, sampling rate should follow the Nyquist theorem to avoid signal aliasing, and frequencies induced by the calibration setup itself could be excluded beforehand, for example, using Helmholtz resonance theory.…”
Section: Calibration Proceduresmentioning
confidence: 99%
“…Table 1 summarizes, in comparative terms and in a qualitative way, the advantages and disadvantages of some of those solutions for pressure calibration purposes. Loudspeaker [16] Y Y Y N 1-10 Pistonphone [17] N N Y N 10-50 Tubing system [10] Y Y N N 20-30,000 Dropping mass [18] N From the previous table, it can be underlined that the main novelties associated with the proposed prototype are its capability to minimize calibration errors due to its remote sense compensation capability and its larger pressure dynamic range, besides its capability to generate arbitrary waveform pressure signals.…”
Section: Introductionmentioning
confidence: 99%
“…Laboratoire national de métrologie et d'essais/Ecole Nationale Supérieure d'Arts et Métiers (LNE/ENSAM) are developing dynamic pressure standards based on shock tube and fast-opening valve principles [1]. VTT MIKES, The National Metrology Institute of Germany (PTB) and the National Metrology Institute of Turkey (TUBITAK UME) have been developing drop weight devices [3,8,9]. The pressure range of these shock tubes is currently up to 7 MPa [10] with a frequency range up to the gigahertz range.…”
Section: Introductionmentioning