2021
DOI: 10.1016/j.jphotochem.2021.113423
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of light stability of DHR123 radio fluorogenic nano clay gel dosimeter by incorporating a new dispersant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(6 citation statements)
references
References 55 publications
0
6
0
Order By: Relevance
“…Because surfactants are known to improve both the dose response and light stability, the effect of a dispersant on the Fe 3+ –DHR123 NC‐RFG characteristics when using a carbon‐ion beam was investigated 46 . In these experiments, N ‐vinylpyrrolidone and pyridine were examined as dispersants.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Because surfactants are known to improve both the dose response and light stability, the effect of a dispersant on the Fe 3+ –DHR123 NC‐RFG characteristics when using a carbon‐ion beam was investigated 46 . In these experiments, N ‐vinylpyrrolidone and pyridine were examined as dispersants.…”
Section: Resultsmentioning
confidence: 99%
“…A two-dimensional (2D) fluorescence gel scanner (GELSCAN-3; iMeasure Inc., Japan) was used to evaluate the florescence intensity distribution of each DHR123 gel sample after irradiation. 32,46 This device was a commercially available flatbed color scanner incorporating a moving optical array that allowed scanning with a charge coupled device (CCD). Measurements were performed with excitation at 465 nm and a resolution of 0.25 mm/pixel together with a focal length of 6 mm.…”
Section: Analyzing Dose-response and Two-dimensional Fluorescence Dis...mentioning
confidence: 99%
See 1 more Smart Citation
“…Fluorescence sensors are also used to measure ionizing radiation doses. [17][18][19][20][21] Usually, the underlying mechanism of these sensors involves a weak uorescence moiety combined with hydroxyl radicals due to water radiolysis, transitioning to a strong uorescence moiety. Accordingly, the dosing can be measured by uorescence methodology.…”
Section: Introductionmentioning
confidence: 99%
“…In recent years, gel dosimeters, which are chemical dosimeters, have been attracting significant attention as promising tools for measuring 3D dose distributions [ 13 , 14 , 15 , 16 , 17 , 18 , 19 , 20 , 21 ]. Various forms of chemical dosimeters are used, such as the Fricke gel dosimeter [ 22 , 23 , 24 ], which uses the oxidation reaction of iron ions, and the polymer gel dosimeter [ 25 , 26 , 27 ], which uses radiation-induced polymerization in a monomer solution.…”
Section: Introductionmentioning
confidence: 99%