2017
DOI: 10.1002/ejlt.201700177
|View full text |Cite
|
Sign up to set email alerts
|

Improvement of sensorial and volatile profiles of olive oil by addition of olive leaves

Abstract: The changes caused by the addition of olive leaves (0, 5, and 10%) during the extraction of olive oil and malaxation time (20, 30, and 30 min) in the volatile profile and sensory attributes of olive oil from cv. Cobrançosa were studied. To investigate such transformations, a central composite designs from the Response Surface Methodology (RSM) was used, retrieving 13 runs combining leaf percentages and malaxation times. Each run was extracted in triplicate (39 olive oils overall). Sensory attributes were impro… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
22
1

Year Published

2018
2018
2024
2024

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 16 publications
(27 citation statements)
references
References 23 publications
4
22
1
Order By: Relevance
“…All the samples extractions were carried out in triplicate. The chromatographic analysis was performed on a Shimadzu GC-2010 Plus equipped with a Shimadzu GCMS-QP2010 SE detector (Malheiro et al, 2017(Malheiro et al, , 2013Pinho et al, 2008). A TRB-5MS (30 m × 0.25 mm × 0.25 μm) column (Teknokroma, Spain) was used.…”
Section: Phenolic Compounds Determinationmentioning
confidence: 99%
“…All the samples extractions were carried out in triplicate. The chromatographic analysis was performed on a Shimadzu GC-2010 Plus equipped with a Shimadzu GCMS-QP2010 SE detector (Malheiro et al, 2017(Malheiro et al, , 2013Pinho et al, 2008). A TRB-5MS (30 m × 0.25 mm × 0.25 μm) column (Teknokroma, Spain) was used.…”
Section: Phenolic Compounds Determinationmentioning
confidence: 99%
“…The volatile profile of olives, crushed and malaxed olive pastes, centrifuged and cleaned olives oils, as well as cleaned olive oil at 4, 8 and 12 months after extraction was carried out through HS-SPME (headspace solid phase microextraction) and GC/MS (gas chromatography with mass spectrometry detector) according to the methodology described by Malheiro et al (2017). Briefly, approximately 3 g of whole fruits, 5 g of crushed and malaxed olive paste, and 3 g of olive oil were used for the volatile characterization.…”
Section: Volatile Characterizationmentioning
confidence: 99%
“…All analyses were carried out in 50 mL glass vials, spiked with an accurate concentration of internal standard (4-methyl-2-pentanol) and volatiles adsorbed to an SPME fiber coated with divinylbenzene/carbonex/polydimethylsiloxane (DVB/ CAR/PDMS 50/30 μm) (Supelco, Bellefonte, USA). The sampling conditions were determined based on a conjunction of the methodologies presented by Malheiro et al (2017) and Peres et al (2013). The samples were conditioned for 5 min at 30°C for an incisive release of the volatile compounds.…”
Section: Volatile Characterizationmentioning
confidence: 99%
“…This type of fiber has been widely used for determination of volatiles in olive oils, showing good effectiveness and reproducibility and a high affinity for compounds of low and medium molecular weights . The olive oil sample was placed in 50 mL vials to avoid any contact with the fiber and to provide efficient extraction, according to the method used in previous studies . Then, 4‐methyl‐2‐pentanol was added as an internal standard (100 ppm in methanol; 10 µL), and the vials were sealed with a polypropylene cap with a silicon septum.…”
Section: Methodsmentioning
confidence: 99%
“…[5,24,28] The olive oil sample was placed in 50 mL vials to avoid any contact with the fiber and to provide efficient extraction, according to the method used in previous studies. [29] Then, 4-methyl-2-pentanol was added as an internal standard (100 ppm in methanol; 10 mL), and the vials were sealed with a polypropylene cap with a silicon septum. The volatiles were released at the selected extraction temperature in a water bath and vigorously stirred with a stir bar (350 rpm) for the time required to allow equilibration in the headspace.…”
Section: Volatile Headspace Solid-phase Microextraction (Hs-spme)mentioning
confidence: 99%