“…Existem várias idéias, princípios e estratégias para a seleção de amostras de transferência 7,20,38,52 . Um algoritmo clássico é o Kennard-Stone (KS), que começa selecionando as duas amostras com a maior distância Euclidiana entre si no espaço X. Para cada uma das amostras restantes, calcula-se a distância mínima com respeito às amostras já selecionadas.…”
Section: Seleção Das Amostras De Transferênciaunclassified
See 1 more Smart Citation
“…Existem várias idéias, princípios e estratégias para a seleção de amostras de transferência 7,20,38,52 . Um algoritmo clássico é o Kennard-Stone (KS), que começa selecionando as duas amostras com a maior distância Euclidiana entre si no espaço X. Para cada uma das amostras restantes, calcula-se a distância mínima com respeito às amostras já selecionadas.…”
Section: Seleção Das Amostras De Transferênciaunclassified
“…Bouveresse et al 52 compararam a seleção do conjunto de amostras de transferência usando o algoritmo KS, baseado nos valores de alavancagem, e um método baseado na maximização da menor distância entre pontos (MSID). Os melhores resultados foram obtidos utilizando-se os algoritmos KS e MSID.…”
Section: Seleção Das Amostras De Transferênciaunclassified
“…However, as many researchers have pointed out, [3][4][5][6] because of subtle differences between the instrumental responses and variational environmental condition, a practical problem to multivariate calibration occurs when an existing model, having been established laboriously, is applied to spectra measured under new environmental conditions or on a separate instrument (which is generally treated as the 'slave' and the original conditions or instrument is treated as the 'master'). For this problem, the traditional solution consists of performing full recalibration in the new situation, which involves the repetition of all calibration measurements with the aim of developing another similar calibration model.…”
Section: Introductionmentioning
confidence: 99%
“…Porém, como um modelo PCR ou PLS é desenvolvido para reconstruir as absorbâncias a cada número de onda medido no instrumento master, significa que serão calculados tantos modelos PCR ou PLS como números de onda existam nos espectros respectivos, sendo a etapa crucial a determinação do número de componentes principais a incluir nos modelos (Bouveresse e Massart, 1996b). Isto será discutido posteriormente.…”
Section: B3 Técnica Da Piecewise Direct Standardization (Pds)unclassified
“…A segunda etapa é o cálculo dos parâmetros de transferência usando os espectros do subconjunto selecionado: para cada comprimento de onda (r 1,j onde 1 indica que corresponde ao instrumento master), as absorbâncias destas amostras obtidas no instrumento master são regredidas em função das absorbâncias correspondentes contidas numa janela espectral de comprimentos de onda vizinhos obtidos no instrumento slave. As técnicas PCR ou PLS podem ser usadas para a regressão (Bouveresse e Massart, 1996b …”
unclassified