Improvements in vision‐related quality of life in blind patients implanted with the Argus II Epiretinal Prosthesis

Abstract: BackgroundThe purpose of this analysis is to report the change in quality of life (QoL) after treatment with the Argus II Epiretinal Prosthesis in patients with end‐stage retinitis pigmentosa.MethodsThe Vision and Quality of Life Index (VisQoL) was used to assess changes in QoL dimensions and overall utility score in a prospective 30‐patient single‐arm clinical study. VisQoL is a multi‐attribute instrument consisting of six dimensions (injury, life, roles, assistance, activity and friendship) that may be affec… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
43
1
1

Year Published

2017
2017
2020
2020

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 51 publications
(45 citation statements)
references
References 22 publications
0
43
1
1
Order By: Relevance
“…The IVI may be more sensitive to change and thus, more useful in evaluating the effectiveness of treatments and interventions. The VisQoL has previously been used in the Argus II retinal prosthesis trials, with significant improvements in half of the dimensions measured (injury, life and roles) . For these reasons, we have elected to use both the VisQoL and IVI in future selection protocols for retinal prosthesis trials.…”
Section: Discussionmentioning
confidence: 99%
“…The IVI may be more sensitive to change and thus, more useful in evaluating the effectiveness of treatments and interventions. The VisQoL has previously been used in the Argus II retinal prosthesis trials, with significant improvements in half of the dimensions measured (injury, life and roles) . For these reasons, we have elected to use both the VisQoL and IVI in future selection protocols for retinal prosthesis trials.…”
Section: Discussionmentioning
confidence: 99%
“…Just recently, some image-processing software modifications have been applied to improve the Argus-II vision regarding edge-detection in grating visual acuity (GVA) leading to better shape and object recognition (Duncan et al, 2017 ).…”
Section: Argus-ii Retinal Prostheses Descriptionmentioning
confidence: 99%
“…Argus II developers have started to work on the next-generation implant with 240 electrodes, which can also be improved by peripheral electrodes. Their eventual goal is to minimize the size of the electrode similar to the retinal ganglion cell bodies, with the capacity of individual cell activation (Duncan et al, 2017 ).…”
Section: Argus-ii Retinal Prostheses Descriptionmentioning
confidence: 99%
See 1 more Smart Citation
“…Retinaimplantate kommen nur für vollständig erblindete Patienten infrage. Auch ermöglichen sie bislang nur die Perzeption von Konturen und Helligkeitsunterschieden, haben jedoch einen sehr positiven Effekt auf die Lebensqualität der Patienten [26].…”
Section: Ush-therapieunclassified