2017
DOI: 10.1063/1.4995727
|View full text |Cite
|
Sign up to set email alerts
|

Improvements of the versatile multiaperture negative ion source NIO1

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1

Relationship

4
2

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 26 publications
0
6
0
Order By: Relevance
“…NIO1 (Negative Ion Optimization phase 1) is a radiofrequency Hion source, built and operated by Consorzio RFX and INFN-LNL, with the aim of studying the production and acceleration of negative ions, to address present and future issues and needs of negative ions sources for neutral beam injectors in fusion reactor (DEMO in particular) [ [1]- [4]]. The NIO1 source is designed to be compact and flexible for the test of new concepts, components and instrumentation.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…NIO1 (Negative Ion Optimization phase 1) is a radiofrequency Hion source, built and operated by Consorzio RFX and INFN-LNL, with the aim of studying the production and acceleration of negative ions, to address present and future issues and needs of negative ions sources for neutral beam injectors in fusion reactor (DEMO in particular) [ [1]- [4]]. The NIO1 source is designed to be compact and flexible for the test of new concepts, components and instrumentation.…”
Section: Introductionmentioning
confidence: 99%
“…2 and 10 of ref. [1]), and the source body. During the experimental campaign, which is object of this paper, the two bias plates were electrically connected outside vacuum and will be hereafter referred as a single bias plate (BP).…”
Section: Introductionmentioning
confidence: 99%
“…The test of such a system in the small negative ion beam system NIO1 the topic of this paper, which describes the feasibility study for a beam driven plasma neutralizer test in a small ion source such as NIO1 [16,17]. Due to its versatility NIO ion source is considered for testing other advanced concept for NBIs [18].…”
Section: Neutralization Efficiency and Beam-driven Plasma Neutralizersmentioning
confidence: 99%
“…The study presented in this paper will show the main measurements obtained by the OES diagnostic on NIO1, during the experimental campaigns in which hydrogen was replaced by a mixture of oxygen (90%) and argon (10 %) [6]. This mixture was preferred to hydrogen to perform the tests for the acceleration system; oxygen is indeed more electronegative than hydrogen, therefore it is possible to extract a higher current of negative ions from the source.…”
Section: Introductionmentioning