1977
DOI: 10.1063/1.1134946
|View full text |Cite
|
Sign up to set email alerts
|

Improvements on the measurements of dielectric constant and dissipation factor in a wide frequency range

Abstract: This paper describes an improved micrometer electrode system for the measurements of dielectric constant, dissipation factor, and mean thickness of sheet specimens in a wide frequency range and its appplication to a series of measuring methods. The influence of the edge capacitance and the residual impedance of this electrode system has been decreased to a negligibly small amount by the adoption of a shield ring and improvements in construction of the electrode system. The characteristics of the system are eas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

1981
1981
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 8 publications
0
3
0
Order By: Relevance
“…4 Another significant difference of the present method from the conventional ones is that what is required for the measurements is not the absolute values of length or voltage but the ratio of lengths or that of voltages. 4 Another significant difference of the present method from the conventional ones is that what is required for the measurements is not the absolute values of length or voltage but the ratio of lengths or that of voltages.…”
Section: S Smentioning
confidence: 98%
“…4 Another significant difference of the present method from the conventional ones is that what is required for the measurements is not the absolute values of length or voltage but the ratio of lengths or that of voltages. 4 Another significant difference of the present method from the conventional ones is that what is required for the measurements is not the absolute values of length or voltage but the ratio of lengths or that of voltages.…”
Section: S Smentioning
confidence: 98%
“…These have a frequency range of 1-70 MHz. Kakimoto and his co-workers [23] extended the method to 200 MHz. Specimens are typically discs or rectangles that are larger than electrodes, but developments described by Heidinger [13] enable disc-and ring-shaped specimens that have smaller diameter than electrodes to be measured.…”
Section: Introductionmentioning
confidence: 99%
“…This limitation is a result of our experimental setup being unsuitable for determining the imaginary part through measurement of the resistive component. 10,11 …”
Section: Introductionmentioning
confidence: 99%